Installation Manual Instruction Manual

Chapter 3: Programming
Concord 4 Installation Manual 75
Output programming
Use these settings to program the output points of any installed
SuperBus 2000 hardwire output module. The installer programs a HOM
output point into the Concord security panel by entering three kinds of
information.
Partition: The system partition (1 to 6).
Trigger: The event that activates the output point. Trigger events can
be partition alarms, trouble conditions, open sensors, etc.
Response: How the output responds to a trigger event.
Only the onboard and SnapCard outputs can be configured for user
control.
To program each of the HOM output point configurations into the
security panel:
1. With the display showing the desired bus device, press #.
2. Press A or B until the display shows OUTPUTS.
3. Press #. The display shows OUTPUT 1.
4. Press A or B to select an output, then press #. The display shows
PARTITION ASSIGN 1.
5. Press 1 to 6 to select the desired partition assignment for this relay.
The display flashes the entered setting. Press # and the display shows
the new setting.
6. Press A or B. The display shows CONFIGURATION tttrr
(current setting). The point configuration number is tttrr, where ttt is the
trigger number and rr is the response number.
7. Enter the desired five-digit configuration number for this relay. The
display flashes the entered setting. Press # and the display shows the
new setting.
8. Press # and repeat the process until all outputs are programmed.
Status beeps
Default: On
This setting determines whether the selected touchpad sounds status
beeps. Each touchpad can be set individually. This feature is usually
turned off for a touchpad that is located in or near bedrooms, to avoid
disturbing sleeping persons.
Key beeps
Default: On
This setting determines whether or not selected touchpads beep when
their buttons are pressed. This feature is usually turned off for a
touchpad that is located in or near bedrooms, to avoid disturbing
sleeping persons.