Installation Manual Instruction Manual

Chapter 3: Programming
92 Concord 4 Installation Manual
Arming
Shortcut: 0660nn
where nn is schedule
number
Default: Off
This setting lets you arm according to a time schedule. This setting will
allow you to arm to away only. There is no disarm schedule.
To attach schedules to arming:
1. Press A or B until the display shows ATTACH SCHEDULES TO
EVENTS.
2. Press # then A or B until the display shows ARMING.
3. To select arm to Away press #.
4. Press # and the display shows SCHEDULE 00 OFF/ON (current
setting). If you want a different schedule, press A or B until the schedule
appears.
5. Press 1 (off) or 2 (on). The display flashes the entered selection.
Press # and the display shows the new setting for the selected
schedule.
6. Repeat the process until all desired schedules are attached.
Energy saver menu
The Energy saver menu lets you set the energy saver module or dialog RF
thermostat low- and high-setpoints. These setpoints override the premises
thermostat allowing the energy saver module or dialog RF thermostat to activate
the furnace/air conditioner.
Low setpoint
Shortcut: 070
Default: 5F
This setting determines the temperature at which the energy saver
module relay closes to activate the furnace. The low setpoint cannot be
set equal to or higher than the high setpoint. Enter the desired
temperature (45 to 89°F).
High setpoint
Shortcut: 071
Default: 9F
This setting determines the temperature at which the energy saver
module relay closes to activate the air-conditioner. The high setpoint
cannot be set equal to or lower than the low setpoint. Enter the desired
temperature (46 to 9F).
Attach lights to sensors menu
This menu lets you assign a light number to a sensor. Each time the sensor is
activated, the attached light will turn on for 5 minutes. When the 5-minute timer
expires, the light will turn off. If the same light is scheduled, it will only turn on
during the schedule time.