8.0 TECHNICAL DATA
8.1 Technical Data for the DV1201/DV1221
Operating data:
Input power:
external DC power source 10.7-15VDC,
2V maximum ripple peak-to-peak @ 12V
PS
Current consumption:
14 mA maximum.
Alarm output:
SPDT relay contact rating 100 mA, 15V, 3W.
Tamper connection:
normally closed tamper switch rated at 100 mA @ 30V.
Alarm indication:
remote LED output for use with DV1208.
stand-by = negative
alarm = open connection
Adjustment:
sensitivity adjustment in 5 steps of approximately 6 dB.
Test output level:
TP1 for measuring the ambient noise.
See wiring and testing.
Range:
See planning instructions.
Tamper heat attack:
Protection from temperature 93 degrees C of drilling
protective plate, magnetic field contact, opening contact,
pry-off contact, low voltage alarm if voltage below 7V.
Operating life:
MTBF 240,000 hours.
Environmental data:
Temperature limits:
operational -4°F to 131°F (-20° to +55° C);
storage -58°F to 158°F (-50°C to +70°C).
Relative humidity:
operational 90% at 86°F (30°C).
Electric field:
max. 5 x 10
4
gauss.
Static discharge:
max. 20kV.
Electric discharge:
max.1.5kV at 0.4m joule; max. 300V at 0.5 joule.
Physical Data:
Dimensions:
3.9in. x 3in. x 1.2in. (10 x 8 x 3cm).
Color:
beige.
Weight:
8.8oz.(250grs.)
8.2 Technical Data for DV1215
Input power:
external DC power source 10.7-15V .2V,
maximum ripple peak-to-peak.
Current consumption:
typical 5 mA.
Sweeping frequency:
6-20 kHz.
Size:
.8in. x .8in. x .4in. (2 x 2 x 1cm).
Model Number Description
DV1201 Structural Vibration Detector for Vaults and Safes
DV1221 Structural Vibrator Detector for ATM and Night Deposit Safe
DV1160 Test Transmitter/Generator
DV1208 Eight-Point Remote Annunciator
DV1209 Summed Remote Annunciator
DV1215 Self-Contained Test Transmitter
DV1218 Plastic Insert for Armored Cable
DV1219 Armored Cable Kit (6’)
DV1220 Recessed Floor Mounting Box
DV1228 Tampered Junction Box
WS300 High Security Cable
ORDERING INFORMATION
12345 SW Leveton Dr.
Tualatin, OR 97062
Tel.: 503.692.4052 Fax: 503.691.7566
U.S. & Canada: 800.547.2556
Technical Service: 800.648.7424
FaxBack: 800.483.2495
CORPORATE HEADQUARTERS
Sentrol reserves the right
to change specifications
without notice.
©1997 Sentrol, Inc.
SENTROL, inc
G-3137-1097
14324 Rev. A