User Manual

Table Of Contents
Chapter 5: Web-Based Management
GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 133
This page includes the following fields:
Object Description
Maximum Power Available Displays the maximum power supply in Watt.
Actual Power Consumption This column shows the real-time total power consumption.
System Power Limit User can modify the value to this column field to limit the total output
power for the system.
Main Supply Voltage This column shows the output voltage of the system for PoE ports.
Firmware Version This column shows the PoE chip’s firmware version.
Port Knockoff Disabled Power Management state where one or more PDs have been powered
down so that a higher priority PD may be powered up and yet not
exceed the maximum total power available for PDs.
AC Disconnect Tick this checkbox to monitor the AC impedance on the port terminals
and removes power when the impedance rises above a certain value, for
a certain period (for details, see the IEEE 802.3af specification).
Capacitive Detection If the port and capacitive detection are enabled, the capacitances state
reads in the voltage result from the constant current. This is then
subtracted from the pre-capacitance voltage to get a charge rate. If this
charge rate is within the window of the PD signatures, the device is
considered to be discovered.
Start Showing with a tick symbol, the system initializes and resets
successfully.
Port The index of PoE ports.
Enable State Check it to enable the PoE function to the port.
Power Limit From
Classification
Check it to decide the power limit method.
When this check box is ticked, the system will limit the power supply to
the powered device in accordance with the related class.
Legacy Check it to support the legacy power devices.
Priority Pull down the selection menu item to choose the priority of power
supplying.
Critical
High
Low
High priority is “Critical”.
Port Limit (<15400) mW User can key in the power limit value which is under 15.4 Watts.
Mode Displays the operating mode of the port.
Current (mA) Displays the operating current of the port.
Voltage (V) Displays the operating voltage of the port.
Power (mW) Displays the power consumption of the port.