KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual
Copyright © 2009, GE Security, Inc. This document may not be copied in whole or in part, or otherwise reproduced except as specifically permitted under US copyright law, without the prior written consent from GE. Document number/revision: 1036547G. Disclaimer The information in this document is subject to change without notice. GE, in keeping pace with technological advances, is a company of product innovation.
iii Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Conventions used in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety terms and symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iv KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Chapter 4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Operating your keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Standard Digiplex mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Preface This is the GE KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual. This document includes an overview of the product and detailed instructions explaining: • • how to install a KTD 405/KTD-405A/KTD-405-2D keypad; and how to program and operate a KTD-405/KTD-405A/KTD-405-2D keypad. There is also information describing how to contact technical support if you have questions or concerns.
2 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual
Chapter 1 KTD-405/405A/405-2D overview This chapter provides an explanation of the conventions in this document and an overview of your keypad. In this chapter: Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Product overview GE Security’s KTD-405 is compatible with all GE Security products including DVMRs, multiplexers, matrix switchers, alarm interfaces, CyberDomes, and Digiplex systems. The KTD-405 can select and switch video, initiate camera tours, and select monitors. The KTD-405A adds audio functionality to the unit, providing two-way voice communication with a built-in speaker, amplifier, and audio microprocessor for automatic volume level.
Chapter 1 KTD-405/405A/405-2D overview Operating modes The KTD-405 can be programmed to operate in two modes: standard Digiplex® or zone (DVMR/multiplexer/ PTZ control). (See Appendix A, Sample configurations and charts for layout samples of these modes.) Note: Be aware that the addressing between domes and multiplexers is offset. When setting up and controlling your cameras in zone mode, refer to Receiver site addressing on page 65.
6 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Zone mode A zone is a remote switching device (multiplexer or DVMRe) that serves a group of cameras. A system can be divided into as many as 32 independent zones, and each zone can have from 1 to 64 cameras (average Zone size is 32, only Matrix switcher supports 64 and is less commonly used) depending on the type of controlling device.
Chapter 2 Installation This chapter shows all the connections you’ll need to make to get your keypad and all the peripheral devices working within a diverse video surveillance network. In this chapter: Installation guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Back panel connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 I/O box connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Installation guidelines Plan your system’s camera and device assignments before installing the system. To help plan your system, use the System planning chart on page 69. And when installing your KTD-405 keypad, follow these guidelines: • • • • • • • • • • • • • Each keypad requires its own I/O box. You can connect multiple I/O boxes to each other (using the RS485 control signals) to establish multiple keypads for controlling one system.
Chapter 2 Installation Note: The keypads ship with an updated I/O box that provides RJ45 ports for the RS-485 data line and an RJ11 port for audio. See Connecting new and old I/O boxes on page 17 for connections between the new and old I/O boxes. For connection details for the old I/O boxes, see Old I/O box connections on page 61. Table 1.
10 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Back panel connections KTD-405/KTD-405-2D connections Adhere to all installation guidelines while making connections, including your local codes and those provided in Installation guidelines on page 8. Figure 5. KTD-405/KTD-405-2D back panel connections A RS-232 programming port (future use) B RS-485 and RS-422 in/out C RS-485 termination switch D RJ45 control cable (GE equipment uses two different RJ45 cables.
Chapter 2 Installation KTD-405A connections Adhere to all installation guidelines while making connections, including your local codes and those provided in Installation guidelines on page 8. Figure 6. KTD-405A back panel connections A RS-232 programming port (future use) E RJ11 audio cable G I/O box B Audio port F Power supply C RS-485 and RS-422 in/out I Power cord D RS-485 termination switch RJ45 control cable (GE equipment uses two different RJ45 cables.
KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual I/O box connections RJ-cable connections The RJ-cable connections make new installations or additional devices easy to connect. If you are replacing an old phone-style I/O box in an existing installation, you can use the existing twisted-pair wires (STP for RS-485 and UTP for RS-422), if desired. See Twisted-pair connections on page 13.
Chapter 2 Installation Twisted-pair connections The twisted-pair connections are available to connect additional devices or for existing installations where individual wires were used to connect to the old phone-style I/O box. Easy-to-use RJ-cable connections are also available on the new I/O box. See RJ-cable connections on page 12. Adhere to all installation guidelines while making connections, including your local codes and those provided in Installation guidelines on page 8. Figure 8.
KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Connecting a multiplexer or DVMRe and domes Adhere to all installation guidelines while making connections, including your local codes and those provided in Installation guidelines on page 8.
Chapter 2 Installation Connecting multiple keypads with RJ45 cables Adhere to all installation guidelines while making connections, including your local codes and those provided in Installation guidelines on page 8. Figure 10. KTD-405, KTD-405-2D, and KTD-405A connections via RJ45 cables Observe polarity for: • audio • RS-422 • RS-485 • 12 VDC power.
KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Connecting multiple keypads with STP cable Adhere to all installation guidelines while making connections, including your local codes and those provided in Installation guidelines on page 8 Figure 11. KTD-405 and KTD-405A connections via STP cables Observe polarity for: • audio • RS-422 • RS-485 • 12 VDC power.
Chapter 2 Installation Connecting new and old I/O boxes Adhere to all installation guidelines while making connections, including your local codes and those provided in Installation guidelines on page 8. Note: For additional connection details about the old I/O boxes, see Appendix D. Old I/O Box Connections. Figure 12. New to old I/O box connection Observe polarity for: • audio • RS-422 • RS-485 • 12 VDC power.
18 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Setting audio attenuation When using a KTD-336 audio converter, set the attenuation jumpers to the ON position (Figure 13). The attenuation jumpers are located on the audio/IO card, which is attached to the keypad’s base plate. When not using an audio converter, leave the attenuation jumpers in their default OFF position. Figure 13.
Chapter 3 Programming This chapter explains the programming modes and goes through the various steps you’ll need to follow to program your keypad. In this chapter: Programming modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Supervisor programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 User programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Remote programming . . . . . . . . . . . . . .
20 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Programming modes There are different programming modes for the keypad: • • • Supervisor programming mode: Establishes such essentials as the keypad’s nonvolatile memory, title and many fundamental operating parameters, and allows flexible system setup. User programming mode: Establishes the keypad’s system architecture for operations. Remote device programming mode: Lets you program system devices such as cameras and VCRs.
Chapter 3 Programming Entering programming modes To enter programming mode, do the following: 1. When you provide power to the unit, the normal operating display appears (Figure 15). Figure 15. Normal operating display CAMERA 0 MONITOR 1 2. Press and hold the key until you hear a tone and see the ENTER PROGRAMMING CODE menu appears (Figure 16). Note: The ENTER PROGRAMMING CODE menu times out after five seconds. Figure 16. ENTER PROGRAMMING CODE menu ENTER PROGRAMMING CODE: 3.
22 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Supervisor programming As explained in Entering programming modes on page 21, to enter the supervisor menus, from the ENTER PROGRAMMING CODE menu, press 1-4-7-6-seq. Note: This is the default factory supervisor programming code sequence. After you install your KTD-405 keypad, be sure to change the supervisor programming code as soon as possible to avoid security problems. To change the programming code, see Figure 27 on page 26 of this menu.
Chapter 3 Programming 2. The keypad address screen is shown in Figure 17 on page 22. A keypad address is a number from 1 to 254 that distinguishes a keypad from other devices. This address is automatically assigned (starting at 99 and proceeding downward in value) when the keypad is first connected into the RS-485 communication line. You can assign higher addresses manually. The address doesn’t change unless you assign a new address or the system configuration changes.
24 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual 6. The keypad lockout priority menu (Figure 21) allows the supervisor to set up a hierarchical relationship amoung keypads in the system so that keypads with a higher priority level can prevent other keypads with lower priority from interfering with PTZ control of cameras. The default value is zero, which disables the priority lockout system functions for this keypad. It will ignore any lockout commands.
Chapter 3 Programming Entering a new preset number or pressing 8. To change key assignments, press the + side of the zoom, focus, or iris keys. will take you to the display shown in Figure 23. Figure 23. PROGRAM SOFT KEYS display PROGRAM SOFT KEYS? _ 9. At the PRESS KEY TO PROGRAM display (Figure 24), press any of the available reprogrammable keys. You can also program the shifted keys by holding the esc key and pressing the key. (See Reprogrammable keys and commands on page 67.) Figure 24.
26 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual 14. Press esc to exit to the PROGRAM SOFT KEYS display. 15. Pressing or the - side of the zoom, focus, or iris key takes you to the CHANGE ACCESS CODES display (Figure 27). If you press +, the menus in Figure 27 will appear in sequence. They allow you to change the codes used to access the user, remote, and supervisor menus. The fourth display in the series allows you to set the access code for the keypad itself.
Chapter 3 Programming 17. Pressing or entering a baud rate value takes you to the SYSTEM CONTROLLER display (Figure 29). A System Controller is used with the HDS (High Density Switch) system to provide more comprehensive control of larger systems. In an HDS system, the keypad asks the System Controller for permission to access resources, including the keypad itself. To allow the keypad to access these resources, press the + key (YES). 18.
28 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual User programming As explained in Entering programming modes on page 21, to enter the user menus, from the ENTER PROGRAMMING CODE menu, press 5-7-9-seq. This brings up the OPERATING MODE menu (Figure 31). Figure 31. OPERATING MODE menu OPERATING MODE: DIGIPLEX The operating mode defines the keypad’s system architecture.
Chapter 3 Programming 6. The following access menus (Figure 33) are used to restrict the keypad from addressing specified sites in the system. The access menus enable you to allow access for each camera, monitor, DSR/VCR, and multiplexer. To move from one type of access menu to another, press or . Note: If you do not want to interrupt viewing at another keypad, program the keypad to address only the monitors within its view. 7. Pressing + displays the following menu (Figure 34).
30 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual 12. By default, the selected monitor number corresponds to the number of the matrix switcher output to which it is connected. For example, if monitor 12 appears in the keypad’s display window and a camera selection is made, the monitor that is connected to output 12 of the matrix switcher switches to that camera. Figure 36.
Chapter 3 Programming Zone menus Remember that the addressing between domes and multiplexers is offset. When setting up and controlling your cameras in zone mode, refer to Receiver site addressing on page 65). To program your keypad in zone mode, do the following: 1. Bring up the OPERATING MODE menu (Figure 38). Figure 38. OPERATING MODE menu OPERATING MODE: ZONE 2. Select ZONE to displays the zone menu (Figure 39).
32 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual 6. The next display mentions zone hubs (Figure 43). A hub is the main controlling device in a zone. Hub choices are DVMRE DUP, CALIBUR MMX, TRIPLEX MUX, DUPLEX MUX, SIMPLEX MUX, MATRIX SWCH, SYM DVR, and DVMRE TRI. 7. The next two menus are used to set the system’s size to restrict the user from calling up unused addresses. They also define the maximum number of keystrokes used to automatically select an address.
Chapter 3 Programming 11. The annunciation menu (Figure 48) is for future use. When annunciation is enabled, the keypad displays the first, second, and third call-in/alarm on thee LCD and stores up to 32 call-in requests. 12. Pressing + and then displays the call tone menu (Figure 49). In annunciation mode, the keypad produces a tone on a call-in request or alarm. This sound can be set to one frequency (single) or to warble between two frequencies (multiple). 13.
34 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Remote programming At the ENTER PROGRAMMING CODE menu, press 9-5-1-seq to display the REMOTE PROGRAMMING menu, which allows you to program devices such as cameras and VCRs, as shown in the tree in Figure 51. Figure 51.
Chapter 3 Programming Quick Shadow Tour 1 programming short cut This section explains how to use the shadow tour 1 programming shortcut. To program a ShadowTour™, do the following: 1. Beginning at the normal operating display, bring up the PROGRAM SHADOW TOUR display (Figure 52) by pressing and holding the esc key, then pressing the tour key. 2. At the PROGRAM SHADOW TOUR display (Figure 53), press the + side of the zoom, focus, or iris key to start recording a shadow tour. 3.
36 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual
Chapter 4 Operation This chapter explains how to operate your keypad. It also describes the different operating modes, standard Digiplex mode and zone mode. In this chapter: Operating your keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Standard Digiplex mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Zone mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Operating your keypad Table 3 shows the default functions for the keypad’s keys in normal and shifted mode (shaded cells). To select the shifted mode, press and hold esc and then press the key. Some keys can be changed to other functions. Reprogrammable keys and commands on page 67 in Appendix A shows which keys can be reassigned. Use the help function (shifted mon key) to find the current function assigned to any key. Table 3.
Chapter 4 Operation Table 3. Normal and shifted key functions (continued) Key Function store With number keys, sets presets and autopan limits for selected camera; accesses sequence programming for Calibur multiplexers. Group. Activates group switching and group sequence initiation. find With number keys, selects PTZ position saved by the previous store command for selected camera site. Step +zoom - Controls the zoom function on selected receiver site’s motorized zoom lens. PTZ lockout on/off.
40 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Table 3. Normal and shifted key functions (continued) Key Function Places selected monitor’s DSR, VCR, or DVMRe in stop mode; esc plus exits play mode in multiplexers. Live. Key for DVMRe live mode selection. Places selected DSR, VCR, or DVMRe in record mode. Home. Sends current camera to preset 0. Toggles selected multiplexer’s full-screen picture between normal and 2X magnification.
Chapter 4 Operation Standard Digiplex mode When you provide power to the unit, the normal operating display appears (Figure 55), showing the current camera number and the current monitor number. Figure 55. Normal operating display CAMERA 0 MONITOR 1 Selecting a monitor There are two ways to enter the number for a new monitor: 1. Press the mon key. 2. Enter one of the following: • • the monitor number including any preceding zeros; or the monitor number directly. 3. Press .
42 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Controlling a camera PTZ. Pan, tilt, and zoom are controlled by the joystick. Zoom is also controlled by the + zoom - key. To pan, move the joystick left or right. To tilt, move the joystick up or down. To zoom, twist the joystick knob clockwise or counterclockwise. Focus. For autofocus, press the autofocus key. To focus manually, use the + focus - key. Iris. The iris is controlled by the + iris -key; + opens the iris and - closes the iris.
Chapter 4 Operation user would realize the error. The keypad will prompt for the final store press, and give a confirmation message that it was actually stored. If the preset number is not in the allowed range, the keypad will give an error message instead of asking for the final press of the store key. Shortcuts There are two types of shortcuts provided by the keypad for setting and recalling presets. They are useful for preset that may be changed or recalled frequently.
44 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Setting autopan limits You can set the left and right autopan limits separately. Left autopan limit To set the limit for the left turn-around point of the camera’s back and forth motion, as wells as the tilt and zoom positions for the autopan, do the following: 1. Position the camera at the desired left limit. 2. Tilt and zoom the camera into the desired position. 3. Press store. Note: Do not attempt to enter a preset number.
Chapter 4 Operation Controlling a recording device When a recording device is selected, it can be controlled by the keypad. (See Table 4, Controlling a recording device and Receiver site addressing on page 65 for details.) Table 4.
46 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual System information menus In standard Digiplex mode, holding mon at the normal operating menu displays three system information menus. These menus show the keypad’s address, version, and system size setting. Use and to navigate through these menus. To exit the system information menus, press from the first menu or press esc. Figure 58.
Chapter 4 Operation Audio Annunciation and alarms When a keypad is programmed for site annunciation, it stacks as many as 32 call-in requests in the order in which they are received. The numbers of the first three sites appear in the keypad’s display window (Figure 60). Figure 60. Normal operating display with annunciation CAM 000 2ND 3RD 1ST To call up the first site: Press the 1st key. The site will be removed from the queue and the waiting requests will move up in order.
48 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Zone mode The LCD displays the zone number and title on the top line and the current camera and monitor numbers on the bottom line (Figure 61). Figure 61. Zone mode main menu ZONE --ZONE TITLE CAMERA --MONITOR To select a zone, press zone and enter the zone number. The LCD displays the zone number and title, which is created during programming.
Chapter 4 Operation Selecting and controlling a DVMRe/multiplexer When a zone is active, the corresponding DVMRe/multiplexer can be controlled by the keypad (Table 5). Table 5.
50 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual To enter a Calibur DVMRe/multiplexer’s programming menus, do the following: 1. Enter the remote programming mode: a. Press and hold . b. Press 9-5-1-seq. 2. Select 1, switcher/multiplexer. 3. Select 2, Calibur. 4. Enter the Calibur address. 5. Press . 6. Enter the Calibur password. To navigate the DVMRe/multiplexer programming menus, see Table 6. Table 6.
Chapter 4 Operation Programming a DVMRe/multiplexer camera sequence If you are using a Calibur DVMRe/multiplexer, set a camera sequence by doing the following: 1. Press store. 2. Press seq. to display the ENTER SEQUENCE menu (Figure 62). Figure 62. Enter sequence menu 3. Enter the number of the first camera in the sequence. ENTER SEQUENCE CAMERA 4. Wait the amount of time you want between cameras, then press the next camera in the sequence. 5.
52 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual
Chapter 5 Troubleshooting and support This section provides information to help you diagnose and solve various problems that may arise while configuring or using your GE Security product and offers technical support contacts in case you need assistance. In this chapter: Troubleshooting your keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Contacting us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
54 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Troubleshooting your keypad This section provides information to help you diagnose and solve various problems that may arise while configuring or using your GE Security product and offers technical support contacts in case you need assistance. (See Contacting us on page 56.) Adhere to all installation guidelines while making connections, including those provided in section Chapter 2, Installation on page 7.
Chapter 5 Troubleshooting and support • I cannot accurately program a shadow tour using RS-485 or ASCII protocols while using KTD-405-2D. While recording shadow tours, RS-422 and ASCII protocols cannot communicate nor record all camera commands while the pan/tilt joystick and zoom buttons are used simultaneously. Use zoom commands separately from pan/tilt commands during shadow tour programming.
56 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Contacting us For help installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, contact us during business hours (Monday through Friday, excluding holidays, between 5 a.m. and 5 p.m. Pacific Time). Table 7. Technical support North America Latin America T: 888 GE Security (888.437.3287). Toll-free in the US, Puerto Rico, and Canada. 503.885.
Appendix A Sample configurations and charts This appendix provides several sample configuration diagrams to help you visualize your system and also includes DIP switch aids, charts, and other helpful information. In this appendix: Sample analog system configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Sample IP system configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Receiver site addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Sample analog system configurations 6 A 7 7 B 8 8 KEYPAD 5 6 9 9 10 10 9 10 9 10 SPEAKER RS485 RS485 RS422 IN RS422 OUT SPEAKER SHIELD + KEYPAD 5 B RS422 OUT AUDIO RS485 RS485 A 4 8 8 6 4 7 7 5 B 3 6 4 RS422 IN EARTH GROUND 3 5 3 RS485 SPEAKER SHIELD + A 2 4 B 2 3 A 1 2 B 2 A 1 1 1 B REMOVABLE TERMINAL STRIP BIAS POWER SWITCH 12 VDC REMOVABLE TERMINAL STRIP BIAS POWER SWITCH 12 VDC EA
Appendix A Sample configurations and charts Figure 64.
KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual 6 A 7 7 B 8 8 KEYPAD 6 SPEAKER SHIELD aux 2 aux 3 aux 4 2 3 seq alarm tour store find 10 10 aux 1 9 dsr/vcr 9 auto focus zone 9 10 9 10 1ST view SPEAKER RS422 IN RS422 OUT SPEAKER SHIELD + RS485 RS485 KEYPAD B 5 RS422 OUT AUDIO RS485 RS485 A 5 RS422 IN 4 8 8 6 4 7 7 5 B 3 6 4 A 3 5 3 RS485 + EARTH GROUND 2 4 B 2 3 A 1 2 B 2 A 1 1 1 B REMOVABLE TERMINAL STRIP BIAS POWER
Appendix A Sample configurations and charts Old I/O box connections Figure 66.
62 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Figure 67.
Appendix A Sample configurations and charts Connecting multiple keypads to the old I/O box Figure 68. Multiple KTD-405 connections A Shield (float) E To/from KTD-405 G RS-422 input (if used) F To additional keypads or multiplexer/ DVMRe (ground at mux/DVMRe) H RS-422 output (to CyberDomes) B 12 VDC in (no polarity) C To/from KTD-405 D 12 VDC in (no polarity) Figure 69.
64 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Sample IP system configuration In Figure 70, the four IP sources are GE Legend IP domes. The domes’ ID addresses need to be programmed as #17, #18, #19, and #20 as the IP inputs. To control them you should have the PTZ units site address set to 16, 17, 18, and 19. The SymDec 16 plus 4 is capable of recording 16 analog video signals and 4 IP streamed video signals. Any video source can be a PTZ (pan/tilt/zoom) device.
Appendix A Sample configurations and charts Receiver site addressing Each receiver has a DIP switch used to assign its site address. To determine the receiver site address, see Table 8, Table 9, and Figure 71 on page 65 and perform the following: 1. Determine which position values must be added together to equal the site number. 2.
66 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Table 9.
Appendix A Sample configurations and charts Reprogrammable keys and commands From the supervisor programming mode you can reprogram any of the soft keys with any of the available commands. Note: Holding the seq key for three seconds returns you to the normal operating display, except on displays where esc is required to exit. To reprogram soft keys, do the following: 1. Beginning at the normal operating display, enter the supervisor programming mode by pressing and holding the key. Figure 72.
68 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual Table 10.
Appendix A Sample configurations and charts System planning chart Switcher Input Type Title Description IP Address (if applicable) Make photocopies of this table to help you plan your system.
70 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual
71 Index A K access code..............................................................................................26 key assignments ......................................................................................25 annunciation................................................................................30, 33, 47 keypad operation.....................................................................................38 audio...................................................................
72 KTD-405/KTD-405A/KTD-405-2D Controller Keypad User Manual T Z technical support .....................................................................................56 zone mode ...........................................................................................6, 48 technical support centers.........................................................................56 troubleshooting .......................................................................................