Installation Manual Instruction Manual

Appendix B: Reporting codes
NX-8V2 Control Panel Installation Manual 69
Loc.
Description
Default
Setting
13
Phone 3 account code
10, 10, 10, 10, 10, 10
14
Phone 3 communicator format
0
15
Phone 3 dial attempts
Backup control
8
0
16
Phone 3 events reported
Segment 1
1 = Alarms and restores
2 = Open/close
3 = Bypass
4 = Zone trouble
5 = Pow er trouble
6 = Siren and telephone fault
7 = Test reports
8 = Program, dow nload and log full
Segment 2
1 - Tampers
2 = Short circuit and ground fault
3 = Sensor lost
4 = Sensor low battery
5 = Expander trouble
6 = Failure to communicate
7 = Zone activity monitor
8 = Reserved
17
Partitions reported to phone 3
Segment 1 = Partitions 1 to 8
1
2
3
4
5
6
7
8
18
Custom communicator format
Segment 1
1 = ON-1800hz transmit, OFF-1900hz
2 = ON-2300hz handshake, OFF-1400hz
3 = ON-cksum parity, OFF-double round
4 = ON-2-digit code, OFF-1-digit code
5-6 = Reserved
7 = ON-20 pps, OFF-10 or 40 pps
8 = ON-10 pps, OFF-20 or 40 pps
Segment 2
1 = ON-pager format
2 = ON-1400/2300 handshake
3 and 4 = Reserved
5 = ON-Contact ID
6 = ON-SIA
7 = ON-Contact ID or 4+3
8 = ON-DTMF
19
Download access code
8, 4, 8, 0, 0, 0 ,0, 0
20
Number of rings to answer
8
21
Download control
Segment 1
1 = Enable tw o-call answering machine defeat
2 = Enable tone sniff answering machine defeat
3 = Require callback before dow nloading
4 = Shutdow n control panel
5 = Lock out local programming
6 = Lock out communicator programming
7 = Lock out dow nload section
8 = Enable callback at autotest interval
22
Download callback number (20 segments)
14 (each segment)
23
Partition 1 feature selection
Segment 1
1 = Quick arm
2 = Re-exit
3 = Auto bypass
4 = Silent panic
5 = Audible panic
6 = Auxiliary 1
7 = Auxiliary 2
8 = Multi-keypress tamper
Segment 2
1 = LED extinguish enable
2 = Require user code for bypassing zones
3 = Bypass sounder alert
4 = AC power/low battery sounder alert
5 = Enable bypass toggle
6 = Enable silent auto arm
7 = Enable automatic instant
8 = Enable instant mode toggle