EN 12 TruVision Analog PTZ Camera
Figure 2: DIP switch settings
SW 1 SW 2
SW1 - ADDRESS
Rx Address = Switch Value
Switch1 Number 1 2 3 4 5 6 7 8
Switch1 Value 1 2 4 8 16 32 64 128
Rx Broadcast Address 0 off off off off off off off off
Rx Address 1 on off off off off off off off
Rx Address 255 on on on on on on on on
SW2 – Baud Rate Settings SW2 – Protocol Settings
Switch2 Number 1 2 3 Switch2 Number 4 5 6
2400 Baud on off off Interlogix/GE Impac RS-
485
off off off
4800 Baud off on off PELCO-D on off off
9600 Baud on on off PELCO-P off on off
19200 Baud off off on Reserved Others
38400 Baud on off on
The rest of above is 9600 Baud
Termination Settings
Switch Number 7 Switch Number 8
Reserved Not Terminated off
Terminated on