TruVision 12/32 Series IP Camera Installation Guide P/N 1072880-EN • REV B • ISS 08JAN15
Copyright © 2015 United Technologies Corporation, Interlogix is part of UTC Building & Industrial Systems, a unit of United Technologies Corporation. All rights reserved. Trademarks and patents Trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Manufacturer Interlogix 2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representative: UTC Fire & Security B.V.
ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-0330 du Canada. European Union directives 12004/108/EC (EMC directive): Hereby, UTC Fire & Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC. 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union.
Content Introduction 2 Product overview 2 Installation 3 Installation environment 3 Package contents 4 Cable requirements 12 Camera description 13 Setting up the camera 17 IR illuminators 18 Accessing the SD card 19 Mounting the bullet camera 19 Mounting the VF dome camera 20 Mounting the outdoor dome camera 25 Using the camera with an Interlogix NVR or Hybrid DVR or another system 30 Using the camera with TruVision Navigator 30 Specifications 30 TruVision IP box cameras 30 TruVision IP VF mini dome 31 TruV
Introduction Product overview This is the installation guide for TruVision 12/32 Series IP camera models: TVC-1201 (1.3MPX IP box camera, PAL) TVC-3201 (1.3MPX IP box camera, NTSC) TVC-1202 (3MPX IP box camera, PAL) TVC-3202 (3MPX IP box camera, NTSC) TVB-1201 (1.3MPX IP bullet camera, 2.8-12mm, PAL) TVB-3201 (1.3MPX IP bullet camera, 2.8-12mm, NTSC) TVB-1202 (3MPX IP bullet camera, 2.8-12mm, PAL) TVB-3202 (3MPX IP bullet camera, 2.
TVD-3203 (1.3MPX IP outdoor dome, 2.8-12mm, NTSC) TVD-1204 (3MPX IP outdoor dome, 2.8-12mm, PAL) TVD-3204 (3MPX IP outdoor dome, 2.8-12mm, NTSC) TVD-1205 (3MPX IP outdoor dome, 8-32mm, PAL) TVD-3205 (3MPX IP outdoor dome, 8-32mm, NTSC) Installation This section provides information on how to install the cameras. Installation environment When installing your product, consider these factors: • Electrical: Install electrical wiring carefully.
immediately if the camera is wet and ask a qualified service person for servicing. Moisture can damage the camera and also create the danger of electric shock. • Servicing: Do not attempt to service this camera yourself. Any attempt to dismantle or remove the covers from this product will invalidate the warranty and may also result in serious injury. Refer all servicing to qualified service personnel. • Cleaning: Do not touch the sensor modules with fingers.
IP box camera Camera C-CS adaptor CD with Configuration manual and TruVision Device Finder Installation manual WEEE and Battery Disposal Installation Guide 5
IP VF bullet camera Camera Back box Template Alarm connector (2 pcs) Screws (4 pcs) 2 Ceiling Mounting 1 1 2 2 1:Screw Hole for Bracket 2:Screw Hole for Mounting Base 1 1 2 6 Screws M4.
Water joint: provide water resistance to network connection.
IP VF dome camera Camera Adaptor: for TVD-CB3 cup base Template 12 VDC Connector: DC jack socket to terminal connectors with positive and negative indicators.
Water joint: provide water resistance to network connection.
IP VF outdoor dome camera Camera Back box Template (flush mount) Template (back box) Drill Template Screws(4 pcs) Screws B (3 pcs) Screws M4 × 9.
Alarm connector(4 pcs) Water joint: provide water resistance to network connection. Installation manual CD with Configuration manual and TruVision Device Finder WEEE and Battery Disposal CAUTION: Use direct plug-in UL listed power supplies marked Class 2/CE certified or LPS (limited power source) of the required output rating as listed on the unit.
Cable requirements For proper operation, adhere to the following cable and power requirements for the cameras. Category 5 cabling or better is recommended. All network cabling must be installed according to applicable codes and regulations. Table 1 below lists the requirements for the cables that connect to the camera. Table 1: Recommended power cable requirements Box camera 12 VDC/24 VAC power wires or PoE (802.3af) VF bullet camera: 12 VDC power jack or PoE (802.
Camera description Figure 1: IP bullet camera 1. Ethernet RJ45 PoE port 8. RS-232 serial port 2. Power supply 9. RS-485 port 3. Reset button 10. Alarm In 4. SD card 11. Audio Out 5. BNC port 6. Ground 12. ABF (automatic back focus) button 7. Alarm Out Installation Guide 13.
Note: 1. To reset the camera to default settings, you need to press and hold the RESET button and power on the camera. After the camera is started up, please still hold the Reset button for about 20 seconds. 2. The type of auto-iris interface is shown as below figure: No. DC-driven 1 Damp- 2 Damp+ 3 Drive+ 4 Drive- Power, Video and GND pins are used when the auto-iris is driven by video. Damp+, Damp-, Drive+ and Drive- pins are used when the auto-iris is driven by DC.
Figure 2: IP VF bullet camera 3 1 2 9 10 7 8 6 5 4 1. Shield 6. Lens cover 2. Mounting base 7. BNC output 3. Back box 8. Alarm I/O 4. Reset button 9. Power supply 5. SD card slot 10.
Figure 3: IP VF dome camera 8 11 3 1 4 7 5 9 10 6 2 1. Dome liner 7. Adaptor 2. Bubble Assembly 8. Reset button 3. Ethernet RJ45 9. RS485 4. Power cable 10. BNC cable 5. Alarm cable 11. SD card slot 6.
Figure 4: IP VF outdoor dome camera 9 8 1 2 6 4 7 5 3 1. Dome liner 6. Ethernet RJ45 PoE port 2. Bubble Assembly 7. Power supply 3. SD card 8. Lens 4. Analog video output 9. Alarm I/O 5. Reset button Setting up the camera Note: If the light source where the camera is installed experiences rapid, wide- variations in lighting, the camera may not operate as intended.
To quickly put the camera into operation: 1. Prepare the mounting surface. 2 Mount the camera on the mounting surface using the appropriate fasteners. See “Mounting the bullet camera” on page 19. 3. Set up the camera’s network and streaming parameters so that the camera can be controlled over the network. For further information, please refer to the “TruVision 12/32 series IP Camera Configuration Manual”. 4. Program the camera to suit its location.
Accessing the SD card Insert a Micro SD card with up to 64GB for local storage as a backup in case, for example, the network fails (see Figure 1 on page 13). The card is not supplied with the camera. For the IP VF mini dome and outdoor dome cameras, point the lens vertically upwards to access the SD card slot. Video and log files stored on the Micro SD card can only be accessed via the web browser. You cannot access the card using TruVision Navigator or a recording device.
3. Hook the camera to the back box with the safety cable. Use the screws to fix the camera to the back box. Mounting the VF dome camera To mount the VF dome camera on a ceiling or wall: 1. 20 Loosen the three screws on the edge of the lower dome with a wrench.
Screws 2. Open the lower dome and remove the black inner liner. 3. Using the drill template, drill three holes in the mounting surface.
Cable hole Screw holes 4. If you want to route the cables behind the dome, drill a cable hole in the ceiling or wall using the drill template. 5. Mount the camera to the ceiling or wall by aligning the housing holes with those in the ceiling. Secure the camera with the supplied screws as shown below.
6. Route the cables through the side hole of the dome by removing the cover. 7. Connect the video output connector to the monitor. Connect the power connector to the power supply. 8. View the camera image using the monitor. Adjust the pan, tilt and azimuth angle. Loosen and adjust the zoom and focus lever to obtain the appropriate angle of view and optimum focus. 2) Zoom and focus adjustment. Loosen the zoom lever and move the lever between T(Tele) and W(Wide) to obtain the appropriate angle of view.
Rotation Tilting Rotation 24 Installation Guide
Mounting the outdoor dome camera To mount the outdoor dome camera on a ceiling: 1. Drill the screw holes on the ceiling with the supplied drilling template. To route the cables from the base of the camera, cut a cable hole in the ceiling. Drill Template 2. Install the mounting base to the ceiling with the supplied screws. 3. Connect the corresponding power cable and network cables. 4. Remove the bubble and liner of the camera.
5. Install the dome camera to the mounting base. 5. Adjust the surveillance angle. 1) Loosen the lock screw besides the lens.
2) Hold the plastic plate and rotate the camera to adjust the panning angle [0~350°]. 3) Push the lens forward and backward to adjust the tilting angle [0~80°]. 4) Rotate the lens to adjust the azimuth angle of the camera [0~350°]. 5) Tighten the lock screw. 0 5 3 n a P 0 8 t l i T ° ° 0 5 3 n o i t a t o R ° 6. Re-attach the dome liner and bubble to the camera.
To mount the outdoor dome camera into a ceiling: 1. Drill the screw holes on the ceiling with the supplied drilling template. Drill Template 2. Remove the housing and liner from the camera. 3.
4. Re-attach the housing and liner.
Using the camera with an Interlogix NVR or Hybrid DVR or another system Please refer to the NVR/DVR user manuals for instructions on connecting and operating the camera with these systems. Using the camera with TruVision Navigator A camera must be connected to an Interlogix NVR or hybrid DVR in order to be operated by TruVision Navigator. Please refer to the TruVision Navigator user manual for instructions on operating the camera with the TruVision Navigator.
Dimensions 69.8 × 58 × 145 mm (2.68” x 2.56” x 5.70 in.) Weight 830g (1.83 lbs.) TruVision IP VF mini dome Electrical Voltage input 12 VDC, PoE (IEEE 802.3af) Power consumption 1.3MPX: Max. 6 W (max. 8 W with IR on) 3MPX: Max. 6.5 W (max. 8.5 W with IR on) Miscellaneous Connectors Alarm: screw terminal RS-485: screw terminal DC power: female connector RJ45: female connector BNC: female connector Operating temperature -30 to +60 °C (-22 to +140 °F) Dimensions Φ 140 × 100 mm (Φ 5.51” × 3.94”in.
TruVision IP VF bullet cameras Electrical Voltage input 12 VDC, PoE (IEEE 802.3af) Power consumption 1.3MPX: Max. 12 W 3MPX: Max. 12.5 W Miscellaneous Connectors DC power: screw terminal RJ45: female connector Alarm: screw terminal Operating temperature -30 to +60 °C (-22 to 140°F) -40°C to +60°C (-40°F to +140°F) , with heater on Dimensions 98 x 105 × 328.8 mm Weight 1700 g (3.75 lbs.
Operating temperature -30 to +60°C (-22 to +140°F) -40 to +60°C (-40 to +140°F), with heater on Φ 159.8 × 146 mm (Φ 6.29” × 5.75”in.) Dimensions Weight 2100 g (4.62 lbs.) Environmental rating IP66, IK10 Pin definitions There are eight wires on a standard UTP/STP cable and each wire is color-coded.
Figure 6: Cross-over cable 1 White/Orange 2 Orange 3 White-Green 4 Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown White/Orange 1 Orange 2 White-Green 3 Blue 4 White/Blue 5 Green 6 White/Brown 7 Brown 8 Please make sure your connected cables have the same pin assignment and color as above before deploying the cables in your network.