User Manual
Table Of Contents
22 TVE-110/410/810/1610 H.264 IP Video Encoder User Manual
2. Check the checkbox to enable SNMP v1 or SNMP v2c, and configure the
read SNMP community (default: public), write SNMP community (default:
private), tap address (default: empty) and trap port (default: 162). You can
also enable both SNMP v1 and SNMP v2c.
3. When the SNMPv3 is enabled, you can configure the read username (default:
public).
Note: SNMPv1, SNMP v2c and SNMPv3 are disabled by default.
4. Select the security level to “no auth, no priv”, “auth, no priv”, “no auth, priv” or
“auth, priv”.
5. When the security level is set to “auth, priv”, configure the Authentication
Algorithm and Privacy Algorithm parameters.
When the security level is set to “no auth, no priv”, the Authentication
Algorithm and Privacy Algorithm parameters cannot be configured.
6. Click Save to save the settings.
To configure Port settings:
1. Click Configuration > Remote Configuration > Network Settings > Port.
The Port window appears.
2. Set the HTTP port, RTSP port and HTTPS port of the camera.
HTTP Port: The default port number is 80.
RTSP Port: The default port number is 554.
HTTPS Port: The default port number is 443.