Chapter 13: Alarm and event setup
102 TruVision NVR 22 (S/P) User Manual
Click Apply to save the settings. Click OK to return to the main window.
4. Click Apply to save the intrusion panel setup parameters.
5. Click Exit to return to live view.
To set up the zones in an alarm panel:
1. From the menu toolbar, click Alarm & Event Setup > Intrusion Zone Setup.
2. Under Select Intrusion Panel, select intrusion panel 1, 2 or 3.
3. Select the desired ID of a zone. The maximum is 32. The number does not have to
match the zone number.
4. Under Zone Number, select the desired zone number. The zone number can be
any valid number of the panel, which does not need to match the zone number.
5. Click Action to define the actions for the selected zone number.
Trigger Channel: Select the cameras that will be recorded when an alarm event is
received. The cameras will be recorded following the main stream
(alarm) parameters. The recordings will be 10 seconds for each
assigned camera.
Arming Schedule: Define the alarm schedule for the actions. You can schedule up to
eight periods in a day. Default is 24 hours.