User Manual

Table Of Contents
12BChapter 13: Alarm and event setup
TruVision NVR 71 User Manual 87
ATS Master (EMEA only)
Advisor Advanced (EMEA only)
NetworX panels
Up to three intrusion panels can be set up in the recorder. Each panel can report up to 32
intrusion zones (a zone is an intrusion panel input).
The panels must support the SIA or XSIA reporting protocol. They can report the following
alarm types to the recorder:
An arming event
A disarming event
An alarm event that has an “A” as a second character in the SIA/XSIA code
A heartbeat alarm
In the intrusion panel, set up the recorder as a normal monitoring station. Use OH version 3 so
that the data format is understood by the recorder.
For NX panels, polling must be enabled in the NX-590E.
To set up the zones in an alarm panel:
1. From the menu toolbar, click Alarm & Event Setup > Intrusion Zone Setup.
2. Under Select Intrusion Panel, select intrusion panel 1, 2 or 3.
3. Under Line Number, select the desired ID of a zone. The maximum is 32. The number
does not have to match the zone number.