User Manual Instruction Manual

Chapter 2: Installation
6 UltraView IP PTZ 36X Camera User Manual
Table 1: Recommended cable requirements
Operation
Cable requirement Max. length
feet meters
Data (RS
-485) Not used
Video
75 ohm RG-59 coaxial cable with BNC ends. 750 228
Alarm
Cat 5 cable (recommended) 1250 381
Network
Cat 5 cable (recommended) 492 150
Power
24 VAC cable. To determine the size of cable needed for individual
applications, see “Power cable size and length requirementsbelow.
Power cable size and length requirements
Use the proper gauge of power cable to ensure proper operation and to avoid
voltage drops. See Table 2 below for the recommended cable gauge for varying
maximum cable lengths and power draws.
Table 2: Recommended power cable gauges based on maximum lengths for an operating
voltage of 24 VAC (±10%)
Wire gauge
mm (diameter)
Power
30 W 40 W
Distance
(feet)
Distance
(m)
Distance
(feet)
Distance
(m)
0.80 94 28 70 21
1.00 150 45 112 34
1.25 238 72 179 54
2.00 603 183 452 137
Installing the camera
For basic operation, you need to connect Ethernet, power and video output
cables to the components in the dome shown in Figure 2 on page 5. For
advanced operation, you can also connect any combination of alarm, relay, or
audio cables to the dome.
A qualified service person, complying with all applicable codes, should perform
all required hardware installation.
Note: After removing the protective foil, it is recommended to clean the bubble in
order to ensure a clear view at all times.