Manual
Chapter 4
Camera assembly, shroud, dome
27
Setting the protocol
CyberDome II can use different protocols for communication. To select a protocol, you must set the protocol
DIP switches to the correct sequence of 1s (on) and 0s (off).
To set the protocol DIP switches to select a protocol, do the following:
1. Locate the protocol DIP switch block (Figure 23 on page 26).
2. Using Table 6, find the DIP switch sequence for the desired protocol and set the switches accordingly.
CyberDome II stores programming settings in NVRAM in both the housing and the PTZ module. If the
protocol switches are not set to one of the copy settings (01111 or 11111) and the two memories are different,
Memory flashes onscreen. When you first log onto the menu system, you will be asked which settings you
would like to use. For more information on protocol functionality with the CyberDome II camera, see
Appendix B, Protocol functionality on page 49
Table 6. Protocols
Protocol Switch position
a
a. 1 = on, 0 = off.
Protocol Switch position
a
Automatic selection
b
b. The Automatic selection will automatically determine only the GE protocols (Digiplex, Impac, and ASCII).
00000 AD RS-422 01010
GE Digiplex RS-422 4800 10000 AD Manchester 10010
GE Impac RS-485 9600 01000 Bosch RS-232 00110
GE ASCII RS-422 9600 11000 Bosch biphase 10110
Pelco D autobaud 00100 Coaxitron 11110
Pelco P autobaud 10100 KD6 10001
Ultrak 9600 01100 Serial update 9600 11011
BBV 01110 Serial update 115200 00111
VCL 11100 Clear settings 10111
Panasonic 11010 Copy settings from PTZ to housing 01111