User guide
6 / 64    P/N 145797999-2 • REV B • ISS 19MAR12 
24 
25 
ST400
CP
26 
SB01
EN: Installation Manual 
Introduction 
The VE735 and VE736 are PIR motion sensors. 
They have a patented verified PIR technology. 
Installation guidelines 
The technology in this detector resists false alarm 
hazards. Nevertheless avoid potential causes of 
instability, such as: 
•  Direct sunlight on the detector 
•  Heat sources within a field of view 
•  Strong draughts onto the detector 
•  Large animals in a field of view 
•  Obscuring the detector’s field of view with large 
objects, such as furniture 
Install the detector so that the expected movement 
of an intruder will be across the fields of view (see 
example in Figure 21, item 1). This is the direction 
best detected by PIR detectors. 
Mounting the detector 
1.  Lift off the custom insert and remove the 
enclosed screw (Figure 1). 
2.  Using a screwdriver, carefully prise open the 
detector (Figure 2). 
3.  Remove the interior part (Figure 3). 
4.  Fix the base to the wall between 1.8 m and 3.0 
m (5.9 to 9.8 ft.) from the floor. For flat 
mounting, use a minimum of two screws (DIN 
7998), at least one in position A and one in 
position B. For corner mounting, use screws in 
positions C or D (see Figures 4 and 5). 
Note: Not all screw positions have pry-off 
tamper. Non pry-off positions are shown in the 
warning box. 
5.  Wire the detector. See Figures 7 and 8. 
Note: All wiring must be provided according to 
National Electrical Code, NFPA 70 and CSA 
C22.1, Canadian Electrical Code, Part I, Safety 
Standard for Electrical Installations. 
Figure 16 shows a single detector wiring, 
Figure 17 — multiple devices connection. 
6.  Select the desired jumper and DIP switch 
settings (see “Setting the detector” on page 7). 
7. 
Replace the interior part (Figure 9). 