User Manual

21-3609E rev1.0 xL Regional Settings Guide
69
Default North America, Australia/New Zealand Input Settings (Pxx1:00 and Pxx1:01)
Input Pt. Circuit/Pt. Type Protection Area
*Buffer Area
Name (Pxxx:01)
P001
NA = 201
Aus/NZ = 301
Entry/Exit Door (w/o access ctrl) 01 01 FRONT DOOR
P002
NA = 202
Aus/NZ = 302
Entry Route - ON Only 01 01 LOBBY MOTION
P003
NA = 204
Aus/NZ = 304
Interior - ON Only 01 01 OFFCE MOTION
P004
NA = 204
Aus/NZ = 304
Interior - ON Only 01 01 INTR MOTION
P005
NA = 204
Aus/NZ = 304
Interior - ON Only 01 01 REAR MOTION
P006
NA = 203
Aus/NZ = 303
Perimeter - Stay & On 01 01 PERIMETER DR
P007
NA = 203
Aus/NZ = 303
Perimeter - Stay & On 01 01 OHD (over head door)
P008
NA = 201
Aus/NZ = 301
Entry/Exit Door (w/o access ctrl) 01 01 REAR DOOR
P009
NA = 203
Aus/NZ = 303
Perimeter - Stay & On 01 01 PERIMETER DR
P010
NA = 203
Aus/NZ = 303
Perimeter - Stay & On 01 01 PERIMETER DR
P011
NA = 203
Aus/NZ = 303
Perimeter - Stay & On 01 01 PERIMETER DR
P012
NA = 203
Aus/NZ = 303
Perimeter - Stay & On 01 01 PERIMETER DR
P013
112
Fire Immediate 01 01 KEYPAD FIRE
P014
013
Hold-up 01 01 KEYPAD PANIC
P015
114
Auxiliary Alert 01 01 KEYPAD EMERG
* A Buffer Area is a secondary area number that the point may also share. Example: a single door that is between 2 areas.
Default UK ACPO, European, China/HK, Netherlands, Switzerland, France Input Settings
(Pxx1:00 and Pxx1:01)
Input Pt. Circuit/Pt. Type Protection Area Buffer Area
Name (Pxxx:01)
P001 080 UK ACPO
201: European,
China/HK,
Netherlands,
Switzerland, France
Custom # 80
(Command Point,
Class: Supervisory.
See Custom Point Programming and
ACPO)
01 01 LCLCMDATEALL
FRONT DOOR: European,
China/HK, Netherlands,
Switzerland, France
P002 201 Entry/Exit Door 01 01 CCT DESCRIP
P003 202 Entry Route 01 01 CCT DESCRIP
P004 204 Interior - ON Only 01 01 CCT DESCRIP
P005 204 Interior - ON Only 01 01 CCT DESCRIP
P006 204 Interior - ON Only 01 01 CCT DESCRIP
P007 204 Interior - ON Only 01 01 CCT DESCRIP
P008 204 Interior - ON Only 01 01 CCT DESCRIP
P009 204 Interior - ON Only 01 01 CCT DESCRIP
P010 204 Interior - ON Only 01 01 CCT DESCRIP
P011 204 Interior - ON Only 01 01 CCT DESCRIP
P012 206 Day Warning 01 01 SIREN TAMPER
Program Section: E001 (Equipment Failures)
E0xxÈ00 Keypad Selections NOTE: “xx” represents the equipment trouble type number: 01 – 16.
(left to right on keypad screen) N America Example:
Name Selections Description Regional Settings Default
Time Delay Enter time delay code from
global time delay table.
00 = undefined
System Tamper can not be
edited.
01··System Tmpr
ÈSave E001È00