User Manual

21-3609E rev1.0 xL Regional Settings Guide 77
Example 7: Simple Two Term OR Equation with Timed Output
Configurable only with Director software and Sent to Panel
Bxxx:00 “? A001.15 Query ”
- Area 1 is not ON
Bxxx:01 “? A002.14 Query ”
- Area 2 is OFF
Bxxx:02 “L 00 Logic ”
- Logical OR operator
additional screen generated with Director software.
Bxxx:03 “T 012 Timer ”
- Timed output, 2 minutes
additional screen generated with Director software.
1. Output Bxxx will turn on for 2 minutes when area 1 changes from on or when area 2 goes off from some other
state.
2. The output will not turn back on again after the 2 minutes expire until area 1 goes On and Area 2 is either STAY or
ON.
3. After these two conditions are met, the output will turn back on as noted in point 1.
Example 8: Flash a LED when a Condition is True
Configurable only with Director software and Sent to Panel using “System – Special Outputs
Bxxx:00 “? A016.24 Query ”
- A point is bypassed in Area 16
Bxxx:01 “? S001.00 Query ”
- Turns 1 sec On, 1 sec Off
Bxxx:02 “L 01 Logic ”
- Logical AND operator
Bxxx:03 “T 000 Timer ”
- Follow (Normal)
When a point is bypassed in area 16, the output will flash 1 second on, 1 second off.
This is achieved by the logical AND of the area condition query and the special On /Off effect available in System –
Special Outputs programming.
Example 9: (Complicated) Flash a LED for 45 Minutes after a Panic Token is Detected in an
Area
Configurable only with Director software and Sent to Panel using “System – Special Outputs
B001:00 “? A001.47 Query ”
- Panic Token used in Area 1
B001:01 “T 019 Timer ”
- Timed Output, 45 minutes
B002:00 “? S001.00 Query ”
- Turns 1 sec On, 1 sec Off
B002:01 “? B001.00 Query ”
- Output 1 is ON
B002:03 “L 01 Logic ”
- Logical AND operator
B002:04 “T 000 Timer ”
- Follow (Normal)
2 separate outputs are used to perform this procedure.
A 45 minute timer is applied to panic tokens detected in area 1 in e.g. output # “B001”.
The output state of B001 (timed output based on panic token in area 1) is used to logically “AND” additional output #
e.g. B002 with the Special System 1 second On/Off selection. The important detail is that we use Follow (Normal)
for output B002, in order for the timer not to re-trigger.
Default Programmable Outputs for Regional Settings
Output # / Location Regional Setting Default Default Codes / Setting Meaning / Operation
B001:00 (motherboard)
B001:01
N America
“? S000.07 Query ”
“T 000 Timer ”
- Follows Alarm Siren
- Follow (Normal)
B001:00 (motherboard)
B001:01
European
“? S000.07 Query ”
“T 000 Timer ”
- Follows Alarm Siren
- Follow (Normal)
B001:00 (motherboard)
B001:01
Aus/NZ
“? S000.06 Query ”
“T 000 Timer ”
- Follows ALARM (BURG / EMERG) & FIRE
siren steady.
- Follow (Normal)
B001:00 (motherboard)
B001:01
China/H.K.
“? S000.07 Query ”
“T 000 Timer ”
- Follows Alarm Siren
- Follow (Normal)
B001:00 (motherboard)
B001:01
Netherlands
“? S000.06 Query ”
“T 000 Timer ”
- Follows ALARM (BURG / EMERG) & FIRE
siren steady.
- Follow (Normal)
B001:00 (motherboard)
B001:01
Switzerland
“? S000.07 Query ”
“T 000 Timer ”
- Follows Alarm Siren
- Follow (Normal)
B001:00 (motherboard)
B001:01
France
“? S000.07 Query ”
“T 000 Timer ”
- Follows Alarm Siren
- Follow (Normal)
B002:00 (motherboard)
B002:01
N America
“? S000.05 Query ”
“T 000 Timer ”
- When system is IN ALARM.
- Follow (Normal)