User's Manual Part 1

Three: Control Center Installation 13
Providing a brighter solution.™
Section 3:
Control Center Installation
Mounting the Control Center
Special code requirements apply to your I-Wave
Control System. To ensure safe installation, please
follow all applicable national state, and local codes
when installing the Control Center.
Locate your Control Center near the pool/spa
equipment pad at least ve feet or more away from
either the pool or spa equipment and at least ve feet
off the ground.
Mounting brackets have been provided to assist you in
your installation.
NOTE: The Control Center is not to be considered
as suitable for use as Service Equipment. Therefore,
it is required to have the appropriate means of
disconnection, circuit isolation, and/or branch circuit
protection installed at the Main Power Panel.
Wiring the System Power
Run wire from the Main Power Panel
to your Control Center and connect the
leads to the Control Center Breaker Base.
See detail in Figure 3-2 at the right.
The breaker base of your Control Center
is capable of handling up to 125 amps.
You must comply with the applicable
local codes and use the proper gauge
wiring from your Main Power panel to
your control center breaker base. The
proper gauge wire will be determined by
the length of wire required and the 125
Max Amp rating.
WARNING: Potentially high
voltages in the Control Center
can create dangerous electrical
hazards, possibly causing death,
serious injury, or property damage.
Turn off the Main Power to the
Control Center to disconnect or
service the I-Wave Control Center.
Figure 3-1Figure 3-1
Earth Ground
From Main
Power
White
(neu)
Black
Red
Ground
Earth Ground
From Main
Power
White
(neu)
Black
Red
Ground
Figure 3-2Figure 3-2