The standard system is shipped with snap-in mechanisms in place inside the enclosure, the panel
mount transceiver attached to the top of the enclosure, with antenna to be attached. Components
are already interconnected and are ready for wiring. System model numbers are designed to
make sure the installation meets local code as follows:
PE45343RC — the basic radio-controlled system.
PE45343RCT1 — a special version with a 100 watt transformer for 12-Volt underwater
lighting, where required by local code. The 100-watt transformer (PA117) can also be
ordered separately for installation into standard model PE45343RC.
PE45343RCT3 — a special version with a 300 watt transformer for 12-Volt underwater
lighting, where required by local code. The 300-watt transformer (PA116) can also be
ordered separately for installation into standard model PE45343RC.
You can order most system components individually to assemble a custom I-Wave system as
desired.
Additional Detail on Key Components
Three-Circuit Clock (P1353ME)
Designed for aftermarket and retrot applications, the P1353ME has the
ability to program up to three different circuits. Choose between ve
pre-programmed modes of operation, which include single speed pump
or 2-speed pump/cleaner pump combinations. In addition, programmed
modes that include auxiliaries can control pumps up to 3 HP as well as
underwater, garden, and/or fountain lighting. Countdown and Override
features allow cycle interruptions when pool/spa service is required.
All timing and protection, associated with lter pump/cleaner pump
combinations and two-speed pumps, has already been integrated into
the software. This mechanism can also be installed into almost any
Intermatic enclosure.
120 or 208-240 Volt Input Voltage
Memory Back-Up
Heater Protection (Fireman Switch)
LCD Readout
Shipping Weight — 3 lbs. (1.4 kg)
Agency Approval — CSA/C-US
CONTACT RATINGS – EACH CIRCUIT, ALL MODES
20A Resistive, 120/240 VAC., 50/60 Hz
20A FLA@120 VAC, 96A LRA@120 VAC, 50/60 Hz
17A FLA@240 VAC, 80A LRA@120 VAC, 50/60 Hz
5 Amps Tungsten, 120/240 VAC, 50/60 Hz
5 Amps Ballast, 120/240 VAC, 50/60 Hz