Enable
Disable
ON/OFF
OK
PULSE
1 2
PROG
PROG
Enable
Disable
ON/OFF
OK
MON
1
INTVL
PROG
WED
3
WED
0
This sets the duration of the On pulse which is manually initiated by
pushing the On/Off button (all models) or by operating a remote switch
(4,8,16circuitmodels). (Similar to a pulse, except you do not select a
day).
• PressProgram(PROG).
• Enable the circuit for which you wish a pulse override. Disable all
others.
• PressPULSE. Do not select a day.
• Keyinthepulseduration(inseconds).Example:12press1,2.
• PressOK.BesuretopressPROG again before programming the next
circuit(s).
Repeat for remaining circuits. Note you cannot have both a pulse and
interval override for any one circuit. Your options are either pulse
override, interval override or manual ON/OFF if neither a pulse or
interval is programmed.
Interval Override
This sets the duration of the ON interval which is manually initiated by
pushing the ON/OFF button (all models) or by operating a remote switch
(4,8,16circuitmodels). (Similar to interval , except you do not
select a day).
• PressProgram(PROG).
• Enable the circuit for which you wish a pulse override. Disable all
others.
• PressINTVL. Do not select a day.
• Keyintheintervalduration(indays,hours,minutes).
Example: 1hour 30 minutes – press 1,3,0.
• PressOK.BesuretopressPROG again before programming the next
circuit(s).
REVIEW, REVISE OR DELETE INFORMATION
To Review Set-Up
BesuretheRUN/SET switch is in the SET position.