User Guide

®
• Disconnectpowerpriortoinstallation
• ConnectFM1D14wiringinaccordancewithallapplicablenationalandlocal
electricalcoderequirements.
WARNING
Risk of Fire or Electric Shock
MODEL:
FM1D14 Series
24-Hour/7-Day Time Switch
Operation and User Instructions
Specifications
Input:
12 VDC (FM1D14-12)
24 VAC and VDC, 50/60 Hz (FM1D14-24)
120 to 277 VAC, 50/60 Hz (FM1D14-AV)
Output:
N.O. Contact
15 A, 277 VAC, General Purpose 1 HP, 240 VAC
10 FLA, 60 LRA, 250 VAC B300 Pilot Duty
½ HP, 120 VAC 8 A, 277 VAC, Ballast
1000W, 120 VAC, Tungsten
N.C. Contact
15 A, 277 VAC, General Purpose ½ HP, 120/240 VAC
10 FLA, 60 LRA, 250 VAC 8 A, 120 VAC, Ballast
12 A, 24 VDC, Resistive
Temperature Rating: +131˚F to -40˚F (+55˚C to -40˚C)
Carryover: 2500 hours fully charged
Description
This manual provides
installation and programming
instructions for the FM1D14
series timer.
Timer
Day
h+ m+
+1h
OVR
Reset
Figure 1. FM1D14 Timer
Mounting the FM1D14 Series Timer
Figure 2. FM1D14 Timer dimensions
The standard FM1D14 timer can be surface mounted inside a
panel or ush mounted. Mount the timer as required. Refer to the
dimension drawing in Figure 2.
Follow this procedure to connect the FM1D14 timer wiring.
1. Make sure supply power is disconnected.
2. Check input and output ratings marked on timer to verify the
product is suitable for your supply voltage, load, and application.
3. Connect the FM1D14 wiring. See Figure 3 for reference.
1.26 in.
[32 mm]
.14 in
[3.56 mm]
1 2 3 4
5
2.36 in.
[60 mm]
.14 in
[3.56 mm]
2.36 in.
[60 mm]
2.13 in.
[54 mm]
Connecting the FM1D14 Series Timer Wiring
Figure 3. Connect FM1D14 wiring (front view shown).
COM NCNO
M
1
2
3 4
5
LOAD
12 VDC
(+) (-)
Typical Wiring (12 VDC Application)
COM NCNO
M
1
2
3 4
5
LOAD
24 VDC
(+) (-)
Typical Wiring (24 VDC Application)
COM NCNO
1
2
3 4
5
LOAD
24-277
VAC
L1 L2/N
Typical Wiring (24-277 VAC Application)
COM NCNO
M
1
2
3 4
5
L1 L2/N
Normally
Open
(Dry Contact)
Normally Closed
(Dry Contact)
M
+
-
+
-
Setting the Time of Day
Follow this procedure to set the time of day and day of the week.
1. Press and release the Reset button with a blunt object to
reset the unit. The timer screen ashes.
2. Press and hold
and h+ simultaneously to access the
12:00 AM screen.
3. Take one of these actions.
If.. Then...
Your time zone currently is
in Daylight Savings Time,
Press the +1h button.
Go to step 4.
Your time zone is not in
Daylight Savings Time
Go to step 4 to set the
current time.
4. Press and hold
and press h+ repeatedly until you
advance to the current hour.
5. Press and hold
and press m+ repeatedly until you
advance to the current minute.
6. Press and hold
and press Day repeatedly until you
advance to the current day.
To set ON/OFF event pair, set ON event and then repeat
procedure to set OFF event. The timer enables up to 7 ON/OFF
event pairs.
1. Press the Timer button.
Dashed lines appear to
indicate no event is set for
event 1.
2. Press Day to select the days
of the week for the ON event.
NOTE: To set the ON event:
Programming Events
MO
TU WE TH
FR SA SU
ON
ON a Specic Day Select: The desired day
Every Day of Week Select: MO, TU, WE, TH, FR,
SA, SU
Every Weekday: Select: MO, TU, WE, TH, FR
Every Weekend: Select: SA, SU
Monday through Saturday Select: MO through SAT
Monday,Wednesday,
Friday
Select: MO, WE, FR

Summary of content (2 pages)