Instructions / Assembly

HEAVY DUTY TIMER
PROGRAM REPEATS EVERY 24 HOURS
TO SET TIMER: (SEE ILLUSTRATION)
1. Insert ON (RED) and OFF (BLACK)
trippers(C) into dial at desired ON
and OFF times.
2. Turn dial CLOCKWISE one or
more complete revolutions until
the correct time-of-day is adjacent
to the time-of-day marker (B).
3. Turn lamp or appliance ON and
plug into timer.
4. Plug timer into electrical outlet.
FOR EARLY ON OR OFF OPERATION,
Turn manual knob (A) counter clockwise to
desired ON or OFF position. Timer will follow next
scheduled automatic operation.
IN CASE OF POWER FAILURE , RESET TIMER, (SEE STEP 2)
Risk of Fire
WATTAGE OF LAMPS OR APPLIANCES BEING CONTROLLED SHOULD
NOT EXCEED CAPACITY OF TIMER.
MODEL: HB114
CONTACT: 2 HP (8 FLA, 48 LRA), (8A. AIRCONDITIONER)
20 A RESISTIVE, 8 A INDUCTIVE ,
768 VA PILOT DUTY, 240 V AC, 60 Hz.
CLOCK MOTOR: 240 VOLT 60 Hz.
MADE IN MEXICO
®
TIME-ALL
(C) TRIPPERS
(B) TIME-OF-DAY MARKER
(A) MANUAL KNOB
LR3730
154--01255
WARNING
INTERMATIC INCORPORATED
SPRING GROVE,ILLINOIS 60081-9698