Installation Guide

PX SERIES LOW VOLTAGE
LANDSCAPE AND SWIMMING
POOL/SPA LIGHT TRANSFORMERS
INSTALLATION
OPERATION &
SERVICE MANUAL
Model: PX50 and PX50S - 50 W Transformers
INPUT: 120 VAC, OUTPUT: 12 VAC or 13 VAC
Read and follow the safety instructions listed below and other basic safety precautions before installation or opera-
tion of this transformer and other associated equipment.
These Safety Transformers are specifically designed to
supply 12 VAC to pool/spa lights, submersible fixtures and
outdoor garden lights. The built-in circuit protection will
disconnect power to the transformer in case of defect or
overload.
SPECIFICATIONS
Enclosure Size: 7
1
/
4
(19.4 cm) high x 5
1
/
4
(13.3 cm) wide
x 4
1
/
2
(11.4 cm) deep. Mounting brackets top and bottom.
Enclosure Type: (A) 0.048” corrosion resistant steel with
electrostatically applied beige coating. (B) 0.036” stainless
steel.
Knockouts: Total of ten
1
/
2
”-
3
/
4
” combination.
(4) bottom, (2) right side, (2) left side, (2) back.
1
GENERAL INFORMATION
Model Input Secondary Output Enclosure
60 Hz.
Lamp Watts (W)* Voltage (VAC)
Type
PX50 120 VAC 0.5 A Max. 50 Max. 12 or 13 A
PX50S 120 VAC 0.5 A Max. 50 Max. 12 or 13 B
* Any combination of bulbs, any tap.
If installation involves running wire through a building structure, special wiring methods are needed.
Do Not submerge transformer.
Do Not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
Select cable for each secondary output in accordance with tables in this manual.
Select power source by combining bulb wattage.
For landscape lighting appliances, low voltage cable shall be buried a maximum of 6 inches (15.2 cm) in order to connect to the
main low voltage cable.
WARNING
Risk of Fire or Electrical Shock

Summary of content (4 pages)