Instructions / Assembly

2
SPECIFICATIONS AND OTHER INFORMATION
INSTALLATION
USEFUL INFORMATION
1. Must be mounted upright. Antenna must be up.
2. Radio Receivers are sensitive to heat. Avoid mounting them
above heater, air conditioner or exposed to afternoon sun.
3. The higher the Receiver Module, the longer its range. For
good range and reliable reception, install modules as high as
practical above ground level with antenna at top.
4. Large metal objects divert radio signals. Avoid mounting
Receiver Modules on metal wall, fence or near large metal
objects.
5. Environmental conditions could effect the operation of the
remote control system. For example, in rain the range may
be less than normal.
6. Certain electric equipment like brush type motors or
electronic gas heater igniters emit radio signals and can
effect the function of the Receiver Module. Avoid mounting
modules near such equipment.
7. To prevent electronic interference, install Receiver Modules
at least 3 feet apart.
A. ON/OFF Switching Application - use Model RC613 or RC613L
Make sure the intended load is within the capacity of the Module,
see ratings on page 1 and other choices on page 4.
1. Attach Receiver Module to the top of an outdoor grade junction
box. Make sure the assembly is raintight.
2. Select the proper location (see Useful Information above) and
install Receiver assembly on a vertical surface or other support,
using hardware, suitable for the purpose.
3. Prepare the necessary conduit runs as required by the installation
layout and pull-in the specied conductors.
4. Follow wiring diagram A on the right, make wire connections as
shown.
5. Turn ON power and test installation, using the ON/OFF button on
face of the Receiver Module. Replace junction box cover, make
sure the installation is secure and raintight.
6. To link transmitter button with the receiver, see Operating
Instructions on page 3.
*Ground connections may or may not be as shown.
Diagram A