Specification

www.intermatic.com
Energy Controls
FF Series
Model Number Time Cycle Switch Hold Color
FF5M 5 Minutes SPST No Brushed Metal Finish
FF5MH 5 Minutes SPST Yes Brushed Metal Finish
FF15MC 15 Minutes SPST No Brushed Metal Finish
FF15MH 15 Minutes SPST Yes Brushed Metal Finish
FF30MC 30 Minutes SPST No Brushed Metal Finish
FF30MH 30 Minutes SPST Yes Brushed Metal Finish
FF60MC 60 Minutes SPST No Brushed Metal Finish
FF60MHC 60 Minutes SPST Yes Brushed Metal Finish
FF2H 2 Hours SPST No Brushed Metal Finish
FF4H 4 Hours SPST No Brushed Metal Finish
FF6H 6 Hours SPST No Brushed Metal Finish
FF6HH 6 Hours SPST Yes Brushed Metal Finish
FF12HC 12 Hours SPST No Brushed Metal Finish
FF12HHC 12 Hours SPST Yes Brushed Metal Finish
FF315M 15 Minutes SPDT No Brushed Metal Finish
FF330M 30 Minutes SPDT No Brushed Metal Finish
FF360M 60 Minutes SPDT No Brushed Metal Finish
FF32H 2 Hours SPDT No Brushed Metal Finish
FF32HH 2 Hours SPDT Yes Brushed Metal Finish
FF34H 4 Hours SPDT No Brushed Metal Finish
FF34HH 4 Hours SPDT Yes Brushed Metal Finish
FF36H 6 Hours SPDT No Brushed Metal Finish
FF312H 12 Hours SPDT No Brushed Metal Finish
FF312HH 12 Hours SPDT Yes Brushed Metal Finish
FF415M 15 Minutes DPST No Brushed Metal Finish
FF430M 30 Minutes DPST No Brushed Metal Finish
FF460M 60 Minutes DPST No Brushed Metal Finish
FF46H 6 Hours DPST No Brushed Metal Finish
FF412H 12 Hours DPST No Brushed Metal Finish
Specification
The timer shall be of the appropriate dimensions and design to provide for direct replacement of a standard wall switch
in a single gang 2 ½" deep junction box. The timer shall include a spiral time scale to provide easy selection of a desired
time setting. Molded white knob and brushed metal nish wall plate shall be a press-on type requiring no screw or other
hardware to secure. The polymeric time dial shall replace a standard switch plate without modications. The timer shall
have a UL listed rating of:
• 1 HP at 125 VAC, 50/60 Hz
• 2 HP at 250 VAC, 50/60 Hz
• 20 Amp, 120 VAC, 50/60 Hz
• 10 Amp, 250 VAC, 50/60 Hz
• 10 Amp, 277 VAC, 50/60 Hz
• 7 Amp, 125 VAC, Tungsten
The timer eld wiring connections shall be secured by means of a teeter-type terminal screw to provide secure
connections for appropriate wire sizes. The timer shall be ___________ (SPST)(DPST)(SPDT). The timer __________ (Shall)
(Shall Not) have a Hold feature and shall have a time cycle of ___________(See Time Cycles Listed). The timer shall be
Intermatic model _______________(See Model Numbers Listed).