Brochure

Mechanical Time Switches
Mechanical Time Switches
31
24-Hour with Skip-a-Day
T170, T1400, and T1800 Series
24-Hour with Skip-a-Day
Similar to the T100 Series, these time switches can also handle
electrical loads up to 40 A per pole. The T170 Series time switches allow
for up to 10 ON/OFF settings per day, but give you the
additional capability of skipping days in which the loads may not be
needed. Each time switch will come with one set of ON/OFF trippers as
well as three skipper screws to omit the schedule for at least three days.
Applications
• For commercial, industrial and residential applications
• Indoor/Outdoor lighting • Signs • Filters • Electric fences • Fans
• Conveyers • Pool heaters • Blowers • Pumps
• Various other electrical loads
Features
• Controls loads up to 40 A per pole
• Direct 24-Hour control of most loads
• Up to 10 ON/OFF operations each day
• Minimum ON/OFF times of one hour
• Manual override
One ON and one OFF tripper and
three day-skipper screws included
Models with Carry-Over (T171CR, T173CR, T174CR, T1471BCR)
Minimum of 16 hours carry-over operation
Carry-over automatically rewinds and only takes one hour for
every two hours of power loss
4PST models are ideal for 3-phase load control
Model # Switch Input Voltage
Metal Indoor Enclosure
T171
SPST 120 VAC, 60 Hz
T172
SPST 208-277 VAC, 60 Hz
T173
DPST 120 VAC, 60 Hz
T174
DPST 208-277 VAC, 60 Hz
T175**
1NO/1NC 120 VAC, 60 Hz
T176**
1NO/1NC 208-277 VAC, 60 Hz
Metal Outdoor Enclosure
T173R
DPST 120 VAC, 60 Hz
T174R
DPST 208-277 VAC, 60 Hz
T1471BR*
4PST 120 VAC, 60 Hz
T1472BR*
4PST 208-277 VAC, 60 Hz
T1475BR*
4PST 480 VAC, 60 Hz
T1871BR*
2NO/2NC 120 VAC, 60 Hz
T171CR
SPST 120 VAC, 60 Hz
T173CR
DPST 120 VAC, 60 Hz
T174CR
DPST 208-277 VAC, 60 Hz
T1471BCR*
4PST 120 VAC, 60 Hz
*Separate clock motor terminals for switching circuits not on line voltage.
**Can be wired as SPDT.
Can be wired as DPDT.
T171CR
Ratings
Resistive 40 A @ varying voltages
Inductive 40 A @ varying voltages
Electronic Ballast 16 A, 277 VAC
Tungsten 40 A @ varying voltages
Pilot Duty 1000 VA @ varying voltages
Motor: T170 Series 2 HP, 24 FLA @ 120 VAC
5 HP, 28 FLA @ 240 VAC
Motor: T1400 and T1800 Series
Single Phase 2 HP, 24 FLA @ 120 VAC; 5 HP, 28 FLA @ 240 VAC
Three Phase 7 1/2 HP, 28 FLA @ 208 VAC; 10 HP, 28 FLA @ 240 VAC
Max Power Consumption 3 W
Operating Temperature -40º F to 130º F (-40º C to 54º C)
Enclosure Dimensions H x W x D
Metal Indoor 7
7
8" x 5
1
8" x 3
7
16" (200 mm x 130.2 mm x 87.3 mm)
Metal Outdoor 10
1
8" x 6 ½" x 3
5
8" (257.2 mm x 165.1 mm x 92.1 mm)
Knockout Dimensions
Side/Back (1) ½" and ¾" combination
Bottom (2) ½" and ¾" combination
Wire Size #8 - #14 AWG
Warranty 1-year
For enclosure options and dimensions, see pages 164-165
Accessories/Replacement
Extra/replacement Trippers,
1 ON and 1 OFF
156T1948A
Extra/replacement Motors:
WG1570-10D for T171, T173, T175, 120 VAC, 60 Hz
WG1571-10D for T171, T173, T175, 120 VAC, 50 Hz
WG1573-10D for T172, T174, T176, 208-277 VAC, 60 Hz
WG430-20D for T1471BR, T1871BR, T1471BCR, 208-277 VAC, 60 Hz
WG433-20D for T1472BR, 208-277 VAC, 60 Hz
Replacement Insulators see pages 168-169
Voltage Ratings
For more details on model
numbers / voltage ratings,
scan the QR code with your
smartphone or tablet.