Operation Manual

6 Scanner SupportChapter
173700 Series Color Mobile Computer User’s Manual
Reading Distances
Typical reading distances are done in an office environment using office
lights (4 lux). Minimum distances are measured in the dark (0 lux). Both
reading distances are provided in respective scan engine integration guides.
Contact your Intermec representative for more information.
Below are minimum standard reading distances for 700 Color Computers
built with integrated scan engines. When correctly mounted, an exit win-
dow reduces reading distances by about 4% for all scan engines, with the
exception of the EL10 with its reading distances re duced by about 25%.
EA10 Minimum Reading Distances with 0.04” Setbacks
Symbology Density Minimum Distance Maximum Distance
Code 39 0.125 mm/ 5 mil
0.15 mm/ 6 mil
0.20 mm/ 8 mil
0.25 mm/ 10 mil
0.30 mm/ 12 mil
0.5 mm/ 20 mil
1.0 mm/ 40 mil
8.03 cm/ 3.16”
7.39 cm/ 2.91”
5.49 cm/ 2.16”
3.96 cm/ 1.56”
3.71 cm/ 1.46”
4.98 cm/ 1.96”
3.71 cm/ 1.46”
11.84 cm/ 4.66”
14.38 cm/ 5.66”
19.46 cm/ 7.66”
24.03 cm/ 9.46”
25.81 cm/ 10.16”
35.97 cm/ 14.26”
50.95 cm/ 20.06”
UPC/EAN 4.98 cm/ 1.96” 29.87 cm/ 11.76”
PDF417 0.168 mm/ 6.6 mil
0.254 mm/ 10 mil
0.381 mm/ 15 mil
7.26 cm/ 2.86”
4.47 cm/ 1.76”
10.06 cm/ 3.96”
12.85 cm/ 5.06”
20.98 cm/ 8.26”
28.35 cm/ 11.16”
Data Matrix 0.254 mm/ 10 mil
0.381 mm/ 15 mil
0.508 mm/ 20 mil
6.50 cm/ 2.56”
5.99 cm/ 2.36”
4.98 cm/ 1.96”
17.93 cm/ 7.06”
27.84 cm/ 10.96”