Appendix A — Specifications and Default Settings
PC23 and PC43 Desktop Printer User Manual 149
Start Adjust Sets the length of media the printer feeds (positive
value) or retracts (negative value) before printing a
label. Unit of measurement is defined in the Unit of
Measure parameter. Range is -9999 to +9999.
0
Stop Adjust Sets the length of media the printer feeds (positive
value) or retracts (negative value) after printing a label.
Unit of measurement is defined in the Unit of Measure
parameter. Range is -9999 to +9999.
0
Media
Calibration
Mode
Selects the mode the printer uses to calibrate media.
Use Slow if the printer has trouble identifying gaps or
marks in media.
Fast
Length
(Slow Mode)
If Media Calibration Mode is set to Slow, the printer
prints the media length plus 10 mm. This value sets an
additional amount of media to be printed. Unit of
measurement is defined in the Unit of Measurement
parameter. Range is 0 to 3200.
0
LTS Sensitivity
Level
Sets the sensitivity of the label taken sensor. Range is 0
to 14. Supported when the Cutter or Label Dispenser
accessories are installed.
0
Setting Description Default