User`s manual
Chapter 4 — Troubleshooting and Maintaining the Printer
96 PF2i and PF4i Mid-Range Printer User’s Manual
Initializing The printer is initializing. Off
IP
configuration
error
The printer is trying to acquire an IP address from
the network. Wait for the printer to complete the
task before taking any action.
Blinking
IP link error No network connection. Blinking
Label not
taken
Label not taken Blinking
LSS too high This error can occur when you run a test feed
without any media installed, or if you have incorrect
media settings. Load the printer with media and
select the appropriate media type. For help, see
“Loading Media” on page 7.
Blinking 1007
LSS too low This error can occur when you run a test feed
without any media installed, or if you have incorrect
media settings. Load the printer with media and
select the appropriate media type. For help, see
“Loading Media” on page 7.
Blinking 1008
Maintenance The printer is upgrading its firmware. Wait for the
printer to complete this task.
Off
Next label not
found
Next label not found Blinking 1031
No RFID
support
installed
The optional RFID interface is not installed in the
printer.
Blinking 1320
No tag found No RFID tag has been found. Blinking 1321
Out of paper The printer is out of paper. Load a new roll of media.
For help, see “Loading Media” on page 7.
Blinking 1005
Out of
transfer
ribbon
The printer is out of transfer ribbon. Load a new roll
of ribbon. For helps, see “Loading Ribbon” on
page 30.
Blinking 1027
Pause Mode
Entered
The print job is paused. Blinking
Power supply
Over
temperature
The power supply is overheated and needs to cool
down.
Off 1718
Fingerprint Error Messages (continued)
Message Description
Ready-to-Work
Indicator Status
Error
Number