User`s manual

Chapter 4 — Troubleshooting and Maintaining the Printer
PF2i and PF4i Mid-Range Printer User’s Manual 97
Press any key
to continue
If an error occurs in the Fingerprint immediate
mode, for example “out of paper” when the print key
is pressed, this event is set.
Off
Printer crash Printer crash. In most instances, when the printer
crashes, the screen is reset which causes the Intermec
Ready-to-Work indicator to turn off.
Off
Printer turned
off
The printer is off. Off
Printhead not
found
Printhead not found. Off
Printhead too
hot
The printhead is overheated and needs to cool down.
You need to resend your print job.
Off 1088
Rebooted The printer has been rebooted. Off
RtW blink by
application
This condition is set by the Fingerprint SYSHEALTH
command. For more information, see the Intermec
Fingerprint Command Reference Manual.
Blinking
RtW off by
application
This condition is set by the Fingerprint SYSHEALTH
command. For more information, see the Intermec
Fingerprint Command Reference Manual.
Off
Setup Mode
Entered
The printer is in Setup mode. Off
Testfeed not
done
The printer did not perform a test feed before it
printed out test labels. Performing a test feed
calibrates the sensor. To perform a testfeed, press the
Print button.
Blinking 1606
Transfer
ribbon is
installed
This is not an error condition. This message briefly
appears after a new roll of transfer ribbon is
installed.
Blinking 1058
Fingerprint Error Messages (continued)
Message Description
Ready-to-Work
Indicator Status
Error