9 / 46
Connection to IR and location
There is no special requirement to match the IR receiver and the Intesis INKNXUNI001I000 interface. Simply
select your model from the list present in the plugin. If your AC unit is not present, please check the compatibility
list as in section 7. You can find more information about the IR configuration in section 5.
Important: Keep in mind that some furniture and materials (carpets, curtains, glass, metal…) may affect
to the IR communication.
Important: The Intesis device has 2 IR emitters pointing at 2 different locations. Considering this and
IR reflections, valid locations for the Intesis device may be many and very different depending on each
installation. Check section 3.1 LOCATION SELECTION for more information.
Intesis INKNXUNI001I000 can be installed in many different locations.
A) Side-by-side with the AC unit B) In front of the AC unit
C) Under the AC unit D) Desktop position
Figure 3.2 IR emitters and IR receiver location
Case A: Installed side-by-side with the AC unit. In that case, the signal will travel from the Intesis device to the
AC unit tacking advantage of the rebounds on the floor or other furniture present in the room.
Case B: Installed in front of the AC unit. In that case, the signal will travel from the Intesis device directly to the
AC unit.
Case C: Installed below the AC unit. In that case, the signal will travel from the Intesis device to the AC unit
tacking advantage of the rebounds on the wall in front of it or other furniture present in the room.
Case D: If you want to place the device on your desktop or any other horizontal surface, please consider the
sketch below. In this case, the signal will travel directly from the Intesis device to the AC unit.