User Guide

(260PO) MODEL ECO7110&8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/07/2014
260
PO
SAVE THESE INSTRUCTIONS
English
Page 25
TROUBLESHOOTING GUIDE
INSUFFICIENT
CHLORINE
WHITEFLAKESIN
THE WATER
NO LED DISPLAY
•
Insufficient operating hours of
the Saltwater System.
•
The salt level in the pool water
is less than 2000ppm. This is
insufficient.
•
Chlorine loss due to intense
sunlight exposure.
•
The bather load has increased.
•
Clogged or dirty electrolytic cell.
• HighUVlevelexposure.
•
Excessive calcium hardness is
present in pool water.
No power supply.
• RCD/GFCIhasnotreseted.
•
A power fuse has blown.
•
LED failure.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
Check the salt level with the Test Kit. Adjust
as needed. See “Salt & Pool Water Volumes”.
Use a pool cover when the pool is not
in use and/or when the unit is operating.
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
Cover the pool with a pool cover for 2
days with the device running and then
test the water using the test strips.
If the pool is clean and clear, add stabilizer
to the water and then test the water with the
device running.
Drainabout20to25%ofthepool
water and add fresh water to decrease
the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean
the electrolytic cell if necessary.
Plug the cell cord firmly into the cell
housing receptacle.
•
Findouttheswitchandturnon.
ResettheRCD/GFCI.
Contact Intex Service Center.
Contact Intex Service Center.
PROBLEM CAUSE SOLUTION