Page 26
TROUBLESHOOTING GUIDE (continued)
INSUFFICIENT
CHLORINE
WHITEFLAKESIN
THE WATER
NOLEDDISPLAY
•
Insufficient operating hours of the
Saltwater System.
•
The salt level in the pool water is less
than 2000ppm. This is insufficient.
•
Chlorine loss due to intense sunlight
exposure.
•
The bather load has increased.
•
Clogged or dirty electrolytic cell.
High UV level exposure.
•
Excessive calcium hardness is
present in pool water.
Nopowersupply.
• RCD/GFCIhasnotreseted.
•
A power fuse has blown.
•
LED failure.
•
Increase the daily Saltwater System operating
time. See “Operating Instructions”.
•
Check the salt level with the Test Kit. Adjust
asneeded.See“Salt&PoolWaterVolumes”.
Use a pool cover when the pool is not in use
and/or when the unit is operating.
Increase the daily Saltwater System operating
time. See “Operating Instructions”.
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
Cover the pool with a pool cover for 2 days
with the device running and then test the
water using the test strips.
If the pool is clean and clear, add stabilizer
to the water and then test the water with the
device running.
Drainabout20to25%ofthepoolwaterand
add fresh water to decrease the calcium
hardness. Inspect the electrolytic cell for scale
buildup. Clean the electrolytic cell if necessary.
Plug the cell cord firmly into the cell housing
receptacle.
ResettheRCD/GFCI.
Contact Intex Service Center.
Contact Intex Service Center.
PROBLEM CAUSE SOLUTION