PRODUCT SPECIFICATIONS
SET UP
Maximum seating capacity: 4 adults 6 adults
Water capacity: 210 gal (795 L) 290 gal (1098 L)
Inner/outer diameter: 57/77 in (145/196 cm) 65/85 in (165/216 cm)
Height: 28 in (71 cm)
Bubble air blower: 1.1 HP / 110-120 V / 60 Hz
Filter pump ow rate: 460 gal/hr (1,741 L/hr)
Heater power: 1,300 Watts / 110-120 V / 60 Hz
Temperature range: 68ºF – 104ºF (20ºC – 40ºC)
Temperature rise: 2-3ºF/hr (1-1.5ºC/hr) 1-2ºF/hr (0.5-1ºC/hr)
Number of Bubble Jets:
140 170
Spa tub recommended working air pressure: 0.083 bar (1.2 psi)
Cord-connected spa with pump, heater, blower, built-in hard water treatment and control panel.
WARNING:
Risk of re: This product draws a minimum of 13 AMPS. Most household circuits are 15 or
20 AMPS. If the circuit breaker trips, please check that no other appliances or other large loads are on the
same circuit as the spa. Never use an extension cord. Unfold the line cord prior to use. Never place the plug
on combustible materials.
Note:
the spa equipment features a complete grounding system that is also in contact with the spa water. It
is possible that a person may build up static electricity that discharges when touching the water. Regardless,
any electric shock experienced should be investigated by a quali ed electrician prior to use of the spa.
Unplug the spa until the cause is determined and any corrective action completed.
Site preparation and requirements
The spa can be installed indoor or outdoor. For household use only.
The spa must be setup on a level, at and smooth surface that is capable of supporting the maximum
load of the lled spa with four adult occupants: weight 2500 lbs (1136 kg); six adults: 3500 lbs (1592 kg).
Make sure the area is free of sharp objects under or around the spa.
Provide adequate drainage system around the spa to deal with over ow water and splashes.
Provide a properly located power outlet to connect the spa and allow easy access for periodic testing of
the cord mounted GFCI/RCD.
Make sure there is enough clearance around the spa for full access to the spa equipment for
maintenance and/or service.
The area shall facilitate draining purposes during long term spa storage.
Additional requirements for indoor installation
Make sure the oor can support the full weight of the lled spa with the maximum number of occupants.
Check with a quali ed contractor or a structural engineer to verify this requirement.
Make sure the oor is water resistant and non-slip surface. Do not install the spa on carpet or other
materials that will be damaged by moisture, condensation.
Do not install the spa indoors on a second oor above nished living space due to the possibility of water
and humidity damage.