Procedure
How to terminate the 6 mm
2
grounding cable to the attached lug of PONE-
OD-DC, proceed as follows:
Step
Action
1
Cut the grounding cable according to the distance between
equipment and grounding bar.
2
Use the blade to strip 1 cm from each end of the cable, as
below:
3
Perform the following actions:
Use the tool with TORX T10 bit to unscrew the terminal lug
from PONE-OD-DC, as shown below:
Slide the M4 grounding lug over the wires at one end of the
cable and crimp it with the special crimping tool.
4
Use the tool with TORX T10 bit to screw the terminal lug onto
the PONE-OD-DC.
5
Terminate the other end of the grounding cable accordingly.
End of procedure.
~
~
1 cm