Specification
Value / Description
Radio Unit
Type
WiBAS
TM
-Connect
Frequency, GHz
28
Antenna
Type
Low profile parabolic
Diameter, m
0.3
Gain, dBi
37.5
Parameter
Power Flux Density Limit, W/m
2
(General Public)
10.0
Compliance Boundary, m (General Public)
1.38
Power Flux Density Limit, W/m
2
(Occupational)
50.0
Compliance Boundary, m (Occupational)
0.62
Specification
Value / Description
Radio Unit
Type
WiBAS
TM
-Connect
Frequency, GHz
26
Antenna
Type
Low profile parabolic
Diameter (m)
0.3
Gain, dBi
37.0
Parameter
Power Flux Density Limit, W/m
2
(General Public)
10.0
Compliance Boundary, m (General Public)
1.20
Power Flux Density Limit, W/m
2
(Occupational)
50.0
Compliance Boundary, m (Occupational)
0.54