Grounding Cable
Introduction
Apply this procedure for installing the grounding cables (GND-KIT16-OD) to
WiBAS
TM
Base Station radio units.
Prerequisites
Prepare and terminate the grounding cable as described in Appendix B
Terminating Cables.
Tools and
materials
Tools
Adjustable torque wrench with hexagon female bit (see
Equipment installation tools).
Materials
Grounding cable.
Radio units.
Procedure for
WiBAS OSDR-
HUB
How to install the grounding cable to WiBAS
TM
OSDR-HUB, proceed as
follows:
Step
1
2
Do not over tighten the M5 nut. Adjust the tool for
applying maximum tightening torque 4.2 Nm.
DO NOT forget to install the other end of the grounding
cable to grounding bar.
End of procedure.