Installation Instructions
WiBAS / WiBAS G5 Base Stations
Installation & Cabling Manual - Edition 3.2
71
Direct Powering / Fiber Optic cable for service Traffic,
Inband Management
Introduction
This paragraph describes the cabling overview of WiBAS
TM
G5 dual-BS
when direct powering is used for power and fiber optic cable is used for
service traffic and inband management.
Maximum
length of DC
power supply
cable used for
direct powering
Due to voltage drop along the length of the powering cable and the minimum
voltage requirements at the input of the radio power supply, restrictions
apply on the length of powering cable
DC-PWR-CAB-3 (2.5 mm
2
) as follows:
DC voltage at input of power cable
Lengths (meters)
42 V DC
60
44 V DC
110
48 V DC
220
54 V DC
>300
Continued on next page