- 1. Place the Master unit on the top of the bin with the lid latches and link cables pointing towards the ground. Place the unit where it is easily accessible for future service and maintenance. The magnetic feet will hold the unit in place on the roo...
- 2. Place the external Remote antenna so that its signal will reach the most Remote units possible. Whenever possible, place the antenna so that it has clear line-of-sight to remote units
- 3. Mount the two solar panels side-by-side on the bin facing the direction of maximum sunlight (face south in the northern hemisphere, face north in the southern hemisphere).
- 4. Place the Master unit battery on the roof of the bin close enough to the master unit that the battery cable will reach the Master unit power cable.
- 5. Connect the Master unit sensor link cable to all the sensing cables and to any other Bin-Sense accessories (e.g. Fan Controllers). You’ll need to use a terminal box or splitter to connect more than one device to the sensor link cable.
- 6. Connect the Master unit power cable to the Master unit battery.
- 7. Connect the Master unit solar panel connections to both solar panels. Both solar panels connections are the same and can be connected to either solar panel.
- 8. Refer to the Bin-Sense Live Startup Manual for further instruction on how to get Bin-Sense Live system up and running.
- CONNECTING TO REMOTE UNITS
- INTENTIONALLY BLANK
Page 14 March 2022 Version 1.0 www.binsense.com
nothing is detected on the sensor cable interface, the LED will flash one red flash followed by a long pause, and
then six red flashes for the radio channel.
EXAMPLE:
If you have one eight-sensor temperature cable, and one eight-sensor moisture cable connected to a Master
unit that is set to radio channel 22, you would expect the following flashing pattern:
• One red flash (for total temperature & moisture cables) followed by two green flashes (for number of
cables).
• Two red flashes (for the total number of sensors) followed by one orange flash (for 10) and six green
flashes (for a total value of 16).
• Three red flashes (for the number of moisture sensors) followed by eight green flashes (for eight).
• Six red flashes (for the radio channel) followed by two orange flashes (for 20) and 2 green flashes (for a
total value of 22).