Installation and User's Guide Network Adapter

Page 72 of 83
Table 11: Adapter to Network Hub Wiring
Connection from the ITI-8241C-S adapter to another network adapter (point
to point) must be made as shown:
Crossover
Adapter 1 Pin Adapter 2
Pin
TX (+) 1 ßà 3 RX (+)
TX (-) 2
ßà
6 RX (-)
RX (+) 3
ßà
1 TX (+)
4 4
5 5
RX (-) 6 ßà 2 TX (-)
7 7
8 8
Table 12: Adapter to Adapter (point to point) Wiring
Network Cabling Requirements
In order for your network to operate properly, you must use a category of
network cabling that is appropriate for the data rate of the channel. For
10Mb/s operation, Category 3, or 5 cable is appropriate. When operating in
100Mb/s or 100Mb/s Full Duplex, a Category 5 cable should be used.
The maximum cable segment length supported at 100Mb/sec speed, on
Category 5 cable is 100M. Any single cable segment (adapter to adapter or
adapter to network hub) must be within the 100M length requirement.