Invacare® TheraPure™ Side Entry Whirlpool Tubs Model 3602GXL Model 3652G User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.
CONTENTS 1 GENERAL 4 Symbols and Signal Words................................................................................................................................................................................................................ 4 Limited Warranty ...............................................................................................................................................................................................................................
CONTENTS 5 OPERATING INSTRUCTIONS 22 Overview .............................................................................................................................................................................................................................................. 22 Cleaning and Disinfecting ...................................................................................................................................................................................................
1 GENERAL 1 General 1.1 Symbols and Signal Words Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. See the information below for definitions of the signal words. ! DANGER Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
1 GENERAL 1.2 Limited Warranty PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser/user of our products. This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state. Invacare Continuing Care, Inc.
2 SAFETY 2 Safety The Safety section contains important information for the safe operation and use of this product. 2.1 General Guidelines ! 2.2 WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment.
2 SAFETY WARNING - PLUMBING WARNINGS - SAFE USE Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes. WARNING - FLOOR LOAD CAPACITY The installation area MUST be able to support the 66 pounds per square inch (45 n/cm²) load capacity of the tub. Otherwise, injury or damage might occur. Use this unit only for its intended use as described in this manual. If any part of the system is not functioning properly, DO NOT use the tub.
3 OVERVIEW 3 Overview 3.1 Features Water Temperature Thermometer Whirlpool On/Off Button Water Temperature Control Fill Button (Push-in once to auto-fill, push-in and hold to add additional water to tub) Invacare® TheraPure™ Side Entry Whirlpool Tubs 8 Part No.
3 OVERVIEW Fill Spout Shower/Massage Wand Overflow Flow Control Valve Adjustment for angle of wand in cradle Shower Spray Adjustment Whirlpool Jet Part No.
3 OVERVIEW 3.2 Product Labeling Model 3652G Labels located inside the Cabinet Door Models 3602GXL Cabinet Door Label located on interior hardware Invacare® TheraPure™ Side Entry Whirlpool Tubs 10 Part No.
3 OVERVIEW 3.3 Typical Product Parameters 3602GXL Weight Tub (shipping weight) Tub (empty) Tub (filled without user) Floor Load Capacity 3652G 324 pounds (147 kg) 274 pounds (124 kg) 380 pounds (172 kg) 66 PSI (45 n/cm²) 313 pounds (142 kg) 263 pounds (119 kg) 350 pounds (158 kg) 66 PSI (45 n/cm²) Minimum Space Requirements: 7 feet x 6 feet Exterior Length/Interior Length: 72 inches/56 inches 67 inches/56 inches Exterior Width/Interior (Seat) Width: 34 inches/23 inches 32 inches/26 inches 42.
3 OVERVIEW 3.4 Minimum Floor Space and Clearance Requirements Model 3602GXL Tub is shown with Model 1900 Traverse lift. 12’ 80” TO 98” 40” MIN 6” to 24” 9” RECOMMENDED SERVICE ACCESS AWAY FROM WALL MINIMUM TUB CLEARANCE Allow for a 40” door swing 9’ 12’ 12” 36” MIN 36” Invacare® TheraPure™ Side Entry Whirlpool Tubs 12 Part No.
3 OVERVIEW Model 3652G Tub is shown with Model 1900 Traverse lift. 12’ 76.5” to 94.5” 6” to 24” 38.5” A ll 9” RECOMMENDED SERVICE ACCESS AWAY FROM WALL doo 5” 38. r sw ing MINIMUM TUB CLEARANCE a for ow 8.5’ 12’ 36” MIN 36” Part No.
3 OVERVIEW 3.5 Dimensions Model 3602GXL Connection Invacare® TheraPure™ Side Entry Whirlpool Tubs 14 Location Type C 9.5” (241 mm) from left side of tub, 5.5” (140 mm) up from floor 3/4” Cold water stub (with recommended shut off valve) D 16.5” (419 mm) inside of the door 2” Drain (floor drain recommended) E 27” (686 mm) from left side of tub, 14” (355 mm) up from floor 115V AC, 60 Hz 15 A Input H 7” (178 mm) from left side of tub, 5.
3 OVERVIEW Model 3652G Connection Part No. 1167457 15 Location Type C 4.625” (117 mm) from centerline, 5.5” (140 mm) up from floor 3/4” Cold water stub (with recommended shut off valve) D 4” (102 mm) from left inside wall, 5” (127 mm) from front inside wall of tub 2” Drain (floor drain recommended) E 4.875” (124 mm) from centerline, 9” (229 mm) up from floor, 4” (102 mm) up from bottom of tub 115V AC, 60 Hz 15 A Input H 4.875” (124 mm) from centerline, 5.
4 INSTALLATION 4 Installation WARNINGS CAUTIONS 4.1 Check all parts for shipping damage. In case of damage, DO NOT use. Contact the carrier for further instruction. The installation area MUST be able to support the 66 pounds per square inch (45 n/cm²) load capacity of the tub. Otherwise, injury or damage may occur. Access for servicing the tub MUST be provided. Install the tub in a location that will permit access to the service panels, plumbing and electrical hookups.
4 INSTALLATION 4.2 Electrical and Plumbing Hook-up Locations on the Tub For installation details, refer to Refer to Electrical Installation on page 19 and Plumbing Installation on page 20. For dimensions, refer to Dimensions on page 14. Model 3602GXL Model 3652G Electrical Line Routing Hole Electrical Line Routing Hole ¾-inch Hot and Cold Water Inlets Hot Water Inlet 2-inch Drain PVC Pipe Part No.
4 INSTALLATION 4.3 Securing the Tub Leg Protective eye wear MUST be worn when drilling to avoid possible eye injury. DO NOT adjust height of legs more than 1 inch (25.4 mm) for Model 3652G or 2 inches (50.8 mm) for model 3602GXL; leg will disassemble from leg mounting pad and serious injury may occur. 1. Set the tub in place. 2. Ensure the plumbing and electrical hook-ups have been installed. 3. Mark the locations of the anchor holes, using pre-drilled holes in leg mounting pads as a template.
4 INSTALLATION 4.5 Electrical Installation DANGERS - ELECTRICAL SHOCK HAZARD WARNINGS Grounding is required. The installation and maintenance of the tub MUST be done by a qualified technician, certified electrician or plumber. Disconnect electrical supply or turn off circuit breaker before installing or performing any maintenance on the tub. The National Electric Code requires the use of a ground fault circuit interrupter on all therapeutic pools and tubs (hydro therapeutic tanks).
4 INSTALLATION 4.6 Plumbing Installation DANGER Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes. WARNINGS Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes. Some state and local plumbing codes require the installation of a “reduced pressure zone” (RPZ) assembly on both the incoming hot and cold supply lines to prevent back flow contamination into the potable water system.
4 INSTALLATION Check local codes regarding maximum water temperature allowed at hot water outlets for facility type. In House Water Service COLD HOT Optional Pressure Regulator Mixing Valve Tub Spout Shower Control Valve Tub Fill Valve Backflow Preventor (located inside tub cabinet) 4.7 Shower Wand Post Installation Checklist Before putting the tub into service, check the following: ❑ Water lines have been purged of any foreign matter.
5 OPERATING INSTRUCTIONS 5 Operating Instructions 5.1 Overview WARNINGS Read and understand ALL information in this manual BEFORE use. Clean and disinfect the tub after EACH use to avoid resident infection and contamination of the tub. DO NOT clean or disinfect the tub when it is occupied. Otherwise injury may occur. To reduce the risk of injury, DO NOT permit children or infirm persons to use this tub UNLESS THEY ARE SUPERVISED AT ALL TIMES.
5 OPERATING INSTRUCTIONS Perform these procedures in the following order: 1. Make sure that the tub has been cleaned, disinfected and BEFORE use. Refer to Cleaning and Disinfecting on page 23. 2. Open the tub door. 3. Transfer the resident to the tub. 4. Use the shoulder and waist straps to help stabilize the resident in the tub as necessary. Refer to Shoulder and Waist Straps on page 27. 5. Fill the tub. 6. Bathe the resident. 7. Drain the tub. 8. Remove the shoulder and waist straps (if used). 9.
5 OPERATING INSTRUCTIONS 1. 2. Use the drain plug to close the drain. Remove and disassemble all jet assemblies. Lay all pieces in the bottom of the tub. • Rotate each jet assembly counterclockwise and pull away from the jet casing. (Detail “A”). • Remove each impeller cap by rotating it clockwise (Detail “B”). • Remove each impeller (Detail “C”). Detail “A” Detail “B” Detail “C” Jet Casing Impeller Cap Impeller Impeller Jet Assembly 3. 4. 5. 6. 7.
5 OPERATING INSTRUCTIONS 8. Replace the impeller and impeller cap on each jet assembly by rotating them counterclockwise. 9. WARNING Jet Casing Cross-threading the jet assembly onto the casing may cause damage to the whirlpool motor. After installation, ensure that the jet assembly is flush against the jet casing. Sanijet® Logo Assemble each jet assembly to the jet casings. • Position the Sanijet® logo and RED indicator at the 11 o’clock position.
5 OPERATING INSTRUCTIONS 5.3 Opening/Closing the Tub Door Door Handle Safety Pin WARNINGS DO NOT open the door when water is in the tub, serious injury could result. DO NOT fill or use the tub if the door does not lock - otherwise serious injury or damage may occur. Model 3602GXL Opening the Tub Door 1. Place one hand on top of the door handle. 2. Use the other hand to pull the safety pin out and release the door handle. 3. Lift up on the door handle and open the door.
5 OPERATING INSTRUCTIONS 5.4 Shoulder and Waist Straps The shoulder and waist straps are a positioning guide only. They are not designed for use as a safety device or as a restraint. The straps MUST be washed and disinfected after each use. Refer to Cleaning and Disinfecting on page 23. Installation On each end of the straps, insert the lead into the round portion of the slot in the attachment point, slide the lead up and turn it. Use 1. 2. 3.
5 OPERATING INSTRUCTIONS 5.5 Water Temperature Setting WARNING The causes, symptoms and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting.
5 OPERATING INSTRUCTIONS 5.6 1. 2. Filling the Tub DANGER - RISK OF SCALDING WARNING Check that the water temperature is between 95° and 105°F (35°C and 41°C) to avoid scalding the resident. Monitor the incoming water temperature on the flow water thermometer. ALWAYS hand test the incoming water temperature and the water temperature in the tub. DO NOT stand in the tub. The tub surfaces are slippery when wet. Serious injury may occur. Close the drain with the blue stopper.
5 OPERATING INSTRUCTIONS Refer to the following chart for shower head adjustment settings. Stream 5.8 1. 2. 3. 4. 5. 6. Pulse Massage Shower Spray Mixture of Shower Spray and Pulse Massage Flow Control serves as a volume control and water saver. The use of the Flow Control permits the reduction of water flow without the need for readjustment of water temperature during bathing. A trickle of water through the Flow Control when in the closed position is normal.
6 INSPECTION AND TROUBLESHOOTING 6 Inspection and Troubleshooting If any part of the system is not functioning properly, DO NOT use the system. For parts and technical service information please contact ICCI Technical Service at (800) 668-2337, Extension 2. 6.1 Safety Inspection Checklists Every six months or as necessary have a qualified technician perform a thorough inspection and servicing. Routine maintenance will extend the life and efficiency of your tub.
6 INSPECTION AND TROUBLESHOOTING 6.2 Troubleshooting If problems are not remedied, contact technical support at 1-800-668-2337, Extension 2.
6 INSPECTION AND TROUBLESHOOTING 6.3 Maintenance Record DATE MAINTENANCE PERSON Part No.
6 INSPECTION AND TROUBLESHOOTING DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED Invacare® TheraPure™ Side Entry Whirlpool Tubs 34 NOTES Part No.
6 INSPECTION AND TROUBLESHOOTING DATE MAINTENANCE PERSON Part No.
Invacare Corporation www.invacare-cc.com USA One Invacare Way Elyria, Ohio USA 44036-2125 Manufacturing Location 899 Cleveland Street Elyria, Ohio 44036 © 2011 Invacare Corporation. All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted.