Invacare ® Therapeutic Support Surfaces Catalog - microAir® Powered Replacement Systems - Solace™ Therapeutic Foam Mattress
Invacare ® Therapeutic Support Surfaces Table of Contents Understanding Pressure Ulcers........................................................3-4 The microAir Difference ..................................................................5-7 MA50, MA51, MA55........................................................................8-9 MA60, MA65 Alternating Pressure ............................................10-11 MA80, MA85 True Low Air Loss ................................................
Invacare ® Therapeutic Support Surfaces Joining the Effort in Pressure Ulcer Prevention There is a national focus on pressure ulcer prevention. In fact, the goal of the Institute for Healthcare Improvement is to reduce incidence by December 2008 and focus on “getting to zero.” The goal of the government’s Healthy People 2010 Initiative is to cut the incidence of pressure ulcers in nursing home residents 50% by 2010. The statistics are worth noting: There are 1.
® ® Therapeutic Invacare Therapeutic Surfaces Invacare SupportSupport Surfaces When is a patient at risk? Patient risk is assessed on a number of factors standardized in assessments such as the Norton or Braden scales. It is recommended that patients be assessed as soon as possible upon entering into care. Fig. B This information is not medical advice. Each individual should always consult with his/her physician to determine proper product selection. What are the risk factors? 1.
® ® Therapeutic Invacare Invacare Therapeutic Support Support Surfaces Surfaces The microAIR® Difference: Security in Design MEDICARE CRITERIA* Support surfaces may be static (nonpowered, reactive) or dynamic (moveable active surface). A static surface is recommended if a patient can assume varying positions without bearing weight on a pressure ulcer, generally a Group I surface.
Invacare ® Therapeutic Support Surfaces Ease of Set Up and Connection Convenient snap on connections for compressor models MA60, MA65 and MA90Z. Unroll the mattress and hook the power unit to the end of the bed. With the snap of the mattress hose onto the plugged-in power unit, the mattress is ready to inflate. Always read the product owner’s manual before use. Always connects correctly.
Invacare ® Therapeutic Support Surfaces Power Outage Safety Compressor models (MA50, MA51, MA55, MA60, MA65 and MA90Z), in the event of a power outage, remain inflated as long as the mattress air hose remains connected to the compressor. Once the power is returned, the memory inside the compressor returns to the programmed settings. Blower models (MA80, MA85 and MA95Z) also return to the pre-power outage settings once the power returns.
® ® Therapeutic Invacare Therapeutic Surfaces Invacare SupportSupport Surfaces Invacare® microAIR® Alternating Pressure Therapeutic Support Mattress Replacement System Model nos. MA50, MA51 and MA55 Invacare® Therapeutic Support Surfaces Invacare ® microAIR® 50 Alternating Pressure Overlay Model no. MA50 The microAIR MA50 is a full featured alternating pressure overlay powered by a 10 LPM compressor with four alternating pressure cycles of 5, 10, 15 and 20 minutes.
Invacare ® Therapeutic Support Surfaces Invacare® microAIR® Alternating Pressure Therapeutic Support Mattress Replacement System Model nos. MA51 and MA55 MA50 / MA51 This Invacare alternating pressure mattress reduces interface pressure to aid in the prevention and the treatment of Stage I to Stage IV pressure ulcers.
Invacare ® Therapeutic Support Surfaces Invacare® microAIR® Alternating Pressure Therapeutic Support Mattress Replacement System Model nos. MA60 and MA65 This Invacare larger alternating pressure mattress reduces interface pressure to aid in the prevention and the treatment of Stage I to Stage IV pressure ulcers with a state of the art 50 LPM compressor that inflates the mattress within 5-10 minutes and provides faster, more efficient and complete therapy cycles.
® ® Therapeutic Invacare Invacare Therapeutic Support Support Surfaces Surfaces Alternating Pressure with On-Demand Low Air Loss and 50 LPM Compressor Model no. MA65 In addition to all of the features of the MA60 alternating pressure mattress, the MA65 model improves air circulation and cools the body temperature with a unique system of air released into the mattress.
Invacare ®® Therapeutic Support Surfaces Invacare® microAIR® True Low Air Loss Therapeutic Support Mattress Replacement Model nos. MA80 and MA85 This Invacare True Low Air Loss mattress helps manage skin moisture to avoid maceration and maintain a dryer environment for pressure For the safety and comfort of the patient and caregiver, the microAIR state of the art controller technology monitors the blower speed to ulcer healing in the treatment of Stage I to Stage IV pressure ulcers.
Invacare ®® Therapeutic Support Surfaces Invacare® Therapeutic Support Surfaces MA85 True Low Air Loss with Alternating Pressure Specifications Electrical Power: 90V, 60Hz, 1A Dimensions: Mattress: 10" x 36" x 80" Power Unit: 14.5" x 11" x 6", 1275 LPM Power Cord: 14 ft. Weight Capacity: 350 lb.
Invacare ® Therapeutic Support Surfaces Lateral Rotation Therapeutic Support Mattress Replacement Systems Model nos. MA90Z and MA95Z These Invacare microAIR lateral rotation mattresses provide pressure relief and moisture maintenance for patients who need to be turned for pressure relief or other health indications. Inherent in the design of the patented z-cell air cell design is alternating pressure as the mattress turns.
Invacare ® Therapeutic Support Surfaces The MA95Z Lateral Rotation with Alternating Pressure and True Low Air Loss with 1275 LPM Blower This model allows for customization of patient therapy settings including 45 degrees of turn, time and pressure. Alternating, static, and pulse therapies are available in addition to the lateral rotation and continuous true low air loss relief.
Invacare ® Therapeutic Support Surfaces Overlays and Foam Mattresses Simple to use and easy to maintain, these products include an alternating pressure pad system, gel overlay and a foam mattress replacement.
Invacare ® Therapeutic Support Surfaces Solace™ Therapeutic Foam Mattresses Solace mattresses are unique dual- and tri-layered foam formulations. They are designed to prevent and relieve pressure ulcers by distributing weight as uniformly as possible, and allowing blood to flow through the capillaries in areas prone to lesion development.* The Prevention, Therapy, and Resolution mattress systems offer good, better and best solutions in static support surfaces.
Invacare ® Therapeutic Support Surfaces Solace™ Prevention Series for low risk patients Solace Prevention 2080 – ™ Head The better mattress choice Model no. SPS2080 Visco-elastic foam heel Built-in Side Supports Added to the design are built-in side supports. The head and heel-soft sections add comfort and protection, while the side-supports provide stability and durability. Solace™ Prevention 3080 – The best solution for low risk patients Model no.
Invacare ® Therapeutic Support Surfaces Solace ™ Therapy 2080 – Solace ™ Therapy 3080 – The better mattress choice for medium to high risk patients The best mattress solution for medium to high risk patients Model no. STS2080 Model no. STS3080 Added to the design are built-in side supports and a Visco heel section to add comfort and protection. Building more into the therapy mattress is a specially designed visco top to cradle the entire body in foam.
Invacare ® Therapeutic Support Surfaces Solace™ Resolution Series – for pressure ulcer treatment The Resolution series is the best Invacare® foam mattress solution for pressure redistribution. SRS1080 Solace ™ Resolution 1080 Series – The best mattress solution for high risk patients Invacare® Therapeutic Support Surfaces Heel slope Model no. SRS1080 Built-in Side Supports Two layers of highest protection foam with a heel slope to alleviate pressure.
Group I Therapeutic Support Surfaces Gel Overlay Model Name Model Number HCPCS Code Patient Risk Level Reimbursement Range* Type of Therapy General Pressure Reduction Invacare® Gel Foam Mattress Overlay IVCGFMO2 E0185 (IN) E0181 (CR) E0184 (IN) Solace™ Prevention Dual Layer Foam Mattresses SPS1080 SPS2080 SPS3080 E0184 (IN) Low Low Medium-High Low Med-High High-Risk & Therapy $271.88 - $338.33 $18.47 - $31.72 $105.34-$194.70 $105.34-$194.70 $105.34-$194.70 $105.34-$194.
Group II Therapeutic Support Surfaces Alternating Pressure Low Air Loss Alternating Pressure Model Name Model Number HCPCS Code Patient Risk Level Reimbursement Range* Type of Therapy Alternating Pressure microAIR® 50 - 5" Overlay microAIR® 51 Mattress microAIR® 60 10" AP Mattress microAIR® 55 AP/LAL microAIR® 65 AP/LAL microAIR® 85 True Low Air Loss AP MA50 Therapy MA51 E0277 (CR) Therapy MA60 E0277 (CR) Therapy MA55 E0277 (CR) Therapy MA65 E0277 (CR) Therapy MA85 E0277 (CR) Therapy $458.
Group II Therapeutic Support Surfaces Low Air Loss Lateral Rotation with Alternating Pressure and Low Air Loss Model Name microAIR® 3500S™ microAIR® 80 microAIR® 90Z Turn/LAL microAIR® 95Z Turn/LAL microAIR® Turn-Q™ Plus Model Number BB9572000 MA80 MA90Z MA95Z BB9612000 HCPCS Code Patient Risk Level Reimbursement Range* Type of Therapy Alternating Pressure Low Air Loss E0277 (CR) Therapy E0277 (CR) Therapy E0277 (CR) Therapy E0277 (CR) Therapy E0277 (CR) Therapy $645.46-$703.47 $645.
Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio 44035-4190 (800) 333-6900 Canada 570 Matheson Blvd. E. Unit 8 Mississauga, Ontario L4Z 4G4 Canada (800) 668-5324 ©2008 Invacare Corporation. All rights reserved. Trademarks are identified by the symbols ™ and ®. All trademarks are owned by or licensed to Invacare Corporation unless otherwise noted. Specifications are subject to change without notification. All products featured are distributed by Invacare Corporation. Form No.