User's Manual

XCRF-860 USER’S MANUAL
11
The length limits to the serial port cable and the
network cable and the selection of network cable (through
line and cross line) should be observed.
The equipment must undergo status test prior to
installation and operation;
During installation and collocation of multiple
readers, the positioning and the minimum distance between
antennas of multiple readers should be observed in order to
avoid interference.
4 Performance Specifications
4.1 Main Functions
Air interface protocol: ISO18000-6C
Tag data rate: 62.5kbps
Number of antennas: maximum 4, controlled by electronic
switches
Isolation between antennas: 22dB
Modulation mode: ASK, PR-ASK
Available frequency points: 50
Emission bandwidth: <400kHz
4.2 Technical specifications
Operating Frequency: 902 to 928MHz