User's Manual

Users Manual to XCRF-502E Reader
Internal use.only. Any transmission is not
allowed without permission.
28
In its default status, XCRF-502E Reader will maintain the
standby status after power on.The Reader has no power emission in
initializing or standby status (RF power amplifier is off); the Reader
will be in the working status only if it is connected to an antenna or a
load and receives the instruction “Read and Write Tag” or “Power
Amplifier On” from the PC.
The Reader will be damaged if the power amplifier is turned on
without a connected antenna or with a dummy load.
5.4.4 Antenna Configuration
The Reader’s read/write range can be preliminarily
confirmed according to the site application. Choose an
installation location of an antenna, fix it, and adjust its
inclination (striking) angle with XCRF-502E Reader’s read
tag test, to make the read distance at the best status.
Finally, fix the antenna’s installation location and
inclination (striking) angle.
5.5 Tests of the Reader
The test of XCRF-502E Reader includes: read tag, write tag, read
distance, write distance, test of read tag information and test of write
tag information.
5.5.1 Read Tag