Installation Guide

I
/O Cable: Top Connector Pin Out for MYCRO, SENSE, TOUCH, SENSE 2 and TOUCH 2
RL
Y_NC
RLY_NO
RLY_COM
ACP_LED2
ACP_LED_GND
ACP_LED1
DAC_IN1
DAC_IN3
DAC_IN2
DAC_GND
D
SP
DAC_OUT
SPI_GND
SPI_2
SPI_1
SPI_3
SPO_GND
SPO_2
SPO_3
SPO_1
Application Label Pin
SPO_1 2
SPO_2 4
SPO_3 6
SPO_GND 8
SPI_1 10
SPI_2 12
SPI_3 14
SPI_GND 16
DAC Output DAC_OUT 18
Door Strike Power* DAC_DSP 20
Wire ColorApplication Label Pin
Relay NC RLY_NC 1
Relay Common RLY_COM 3
Relay NO RLY_NO 5
ACP LED 1 Feedback ACP_LED1 7
ACP LED 2 Feedback ACP_LED2 9
11 Ground for ACP LED Feedback ACP_LED_GND
DAC Input 1
DAC_IN1 13
DAC Input 2
SPO Line 1
SPO Line 2
SPO Line 3
Ground for SPOs
SPI Line 1
SPI Line 2
SPI Line 3
Ground for SPI DAC_IN2 15
DAC Input 3 DAC_IN3 17
Ground for DAC Inputs DAC_GND 19
Wire Color
F
ront View
Back View
W
ired Back Cover
18
*
For SENSE 2 and TOUCH 2 models only
C
opyright 2019
INVIXIUM