DAC:
The IXM device powers the door strike in this configuration. Only applicable to SENSE 2 and TOUCH 2.
Device can supply 500mA@12V
Snubber Diode required for Door Strike (not included)
Example above shows use of RLY_NO, but RLY_NC may be used instead if required by the Door Strike
Internal Relay rated upto max of 2A @ 24 VDC
For motion detector instead of Request-to-Exit-buttom, connect the following signals:
(1) DAC_OUT to the COM and (2) DAC_IN2 to the Relay NO of the motion detector
DAC Connections for Device Powers Door Strike (SENSE 2 and TOUCH 2 only)
D
AC_IN1
DAC_OUT
DAC_OUT
DAC_IN2
Door Contact
Request to exit
T
OUCH 2
DAC Connections
RLY_NC
RLY_COM
RLY_NO
DAC_IN1
DAC_IN2
DAC_OUT
DAC_DSP
DAC_GND
*
Max Relay Rating = 2 Amp @ 24 VDC