Instruction Manual
Table Of Contents
- Glossary of terms
- 1. This manual
- 2. Safety
- 3. Get to know SBV System Series
- 4. Functioning principles
- 4.1 Sensor functioning principles
- 4.2 Detection fields
- 4.3 Safety working modes and safety functions
- 4.4 Safety working mode: Both (default)
- 4.5 Safety working mode: Always access detection
- 4.6 Safety working mode: Always restart prevention
- 4.7 Restart prevention function: static object detection option
- 4.8 Features of the restart prevention function
- 4.9 Muting
- 4.10 Anti-tampering functions: anti-rotation around axes
- 4.11 Anti-tampering functions: anti-masking
- 5. Sensor position
- 6. Installation and use procedures
- 7. Maintenance and troubleshooting
- 8. Technical references
- 9. Appendix
14
SBV System Series| Instruction manual v1.2 DEC 2021 |SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
3. Get to know SBV System Series
3.2 SBV System Series control units
3.2.1 Control units supported
The SBV System Series supportsthree different control units. The main difference among them are the
connection ports and therefore the communication interfaces available:
l ISC-B01: two Ethernet ports for Fieldbus, an Ethernet port for system configuration and Modbus
communication and a micro-USB port
l ISC-02: an Ethernet port for system configuration and Modbus and a micro-USB port
l ISC-03: a micro-USB port
Safe
Unsafe
ISC-B01 communication architecture.
ISC-02 communication architecture.
ISC-03 communication architecture.
3.2.2 Functions
The control unit performs the following functions:
l Collects information from all the sensors via CAN bus.
l Compares the position of detected motion with the set values.
l Deactivates the dedicated safety output when at least one sensor detects motion in the detection field.
l Deactivates all the safety outputs if a failure is detected in one of the sensors or the control unit.
l Manages the inputs and outputs.
l Communicates with the Inxpect Safety application for all configuration and diagnostic functions.
l Allows dynamically switching between different configurations.
l Communicates with a safety PLC through the safe Fieldbus connection (if available)
l Communicates and exchanges data through Modbus protocol (if available)