Instruction Manual

Table Of Contents
4.11.6 Checks when the anti-masking function is disabled
When the anti-masking function is disabled, perform the following checks.
Safety function Schedule Action
Access detection
function
Before each machinery restart Remove any objects that obstruct the field of view
of the sensor.
Reposition the sensor according to the initial
installation.
Restart prevention
function
Each time the safety outputs are
deactivated
4.11.7 When to disable
The anti-masking function should be disabled under the following conditions:
l (with restart prevention function) the monitored area includes moving parts that stop in different and
unpredictable positions,
l the monitored area includes moving parts that vary their position while the sensors are in muting,
l the sensor is positioned on a part that can be moved,
l the presence of static objects is tolerated in the monitored area (e.g. loading/unloading area).
4. Functioning principles
SBV System Series| Instruction manual v1.2 DEC 2021|SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
41