5.2 Sensor field of view
5.2.1 Types of field of view
During the configuration phase, for each sensor it is possible to select the angular coverage of each field in a
range from 10° to 100°. See "Angular coverage" on page28.
The actual detection field of the sensor also depends on the sensor installation height and inclination. See
"Calculation of range of distances" on page46.
5.2.2 Areas and dimensions of the field of view
The sensor field of view is composed of two areas:
l detection field [A]:where detection of objects similar to humans in any position is guaranteed.
l tolerance area [B]:where the actual detection of a moving object/person depends on the characteristics of
the object itself (see "Factors that influence the reflected signal" on page27).
Dimensions for the access detection function
Note: the tolerance area dimensions described are related to the detection of humans.
The tolerance area is 20° greater than the angular coverage set.
Top view
Side view
5. Sensor position
SBV System Series| Instruction manual v1.2 DEC 2021|SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA