Instruction Manual

Table Of Contents
6. Installation and use procedures
Contents
This section includes the following topics:
6.1 Before installation 51
6.2 Install and configure SBV System Series 52
6.3 Validate the safety functions 59
6.4 Manage the configuration 61
6.5 Other functions 62
6.1 Before installation
6.1.1 Materials required
l Two tamper-proof screws (see " Tamper-proof screws specifications" on page81) to mount each sensor.
l Cables to connect the control unit to the first sensor and the sensors to one another, see "CAN bus cables
recommended specifications" on page81.
l A data micro-USB cable or, only if the Ethernet port is available, an Ethernet cable to connect the control unit
to the computer.
l A bus terminator (product code: 07000003) with resistance of 120 Ω for the last sensor of the CAN bus.
l A screwdriver for tamper-proof screws (" Tamper-proof screws specifications" on page81) to be used with the
Hex pin security bit supplied in the control unit package.
6.1.2 Operating system required
l Microsoft Windows 7 or later
l Apple OS X 10.10 or later
6.1.3 Install the Inxpect Safety application
Note: if the installation fails, the dependencies needed by the application may be missing. Update your operating
system or contact our Technical Support team to receive assistance.
1. Download the application from the www.inxpect.com/industrial/tools website and install it on the computer.
2. With Microsoft Windows operating system, download and install from the same site also the driver for USB
connection.
3. Start the application.
4. Choose the connection mode (data micro-USB or Ethernet).
Note: the default IP address for the Ethernet connection is 192.168.0.20. The computer and the control unit
must be connected to the same network.
5. Set a new admin password, memorize it and provide it only to people who are authorized to change the
configuration.
6. Select the device (SBV System Series).
7. Set the country in which the system is installed and the application type.
6.1.4 Initiate SBV System Series
1. Calculate the position of the sensor (see "Sensor position" on page42) and the depth of the dangerous area
(see "Dangerous area calculation" on page45).
2. "Install the control unit" on the next page.
3. Open the Inxpect Safety application.
4. Optional. "Synchronize the control units" on the next page.
5. "Define the area to be monitored" on the next page.
6. "Configure the inputs and outputs" on the next page.
7. Optional. "Mount bracket for z-axis rotation (roll)" on page55.
8. "Install the sensors" on page53
SBV System Series| Instruction manual v1.2 DEC 2021|SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA