6.2.5 Install the sensors
Note: for an example of sensor installation, see "Examples of sensor installation" on page56.
1. Position the sensor as indicated in the
configuration report and fasten the bracket
with two tamper-proof screws directly onto the
floor or another support.
NOTICE: make sure the support does not inhibit
machinery commands.
2. With an Allen key, loosen the screw at the
bottom to pan the sensor.
3. Pan the sensor until it reaches the desired
position.
Note: a notch is equal to 10° of rotation.
4. Tighten the screw.
6. Installation and use procedures
SBV System Series| Instruction manual v1.2 DEC 2021|SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA